4. Error Handling:
ERROR
CODE
A1
A2
A3
A4
A5
A6
Exhaust temperature
A7
A8
A9
Screen no display or
- -
NOTE:
1. When the unit has error, the buzzer of the operation panel will make an alarm sound, and there will
show "Alarm" on the screen panel.
2. "ERROR CODE" will show on temperature display location by alternately.
3. Part of the error alarm can be automatically restored (resumed). That is the appeared alarm can be
eliminated by electronically controlled self-test.
4. Some of the error alarm is caused by large fluctuation of the external power, by this, just power off and
restart the unit to clear the error.
5. When the machine has error alarm and restart still can not eliminated error, please contact the after
service as soon as possible for solution.
ERROR STATUS
Thermal sensor
alarm
Condenser coil
sensor alarm
Exhaust sensor
alarm
Ambient temp.
sensor alarm
Low /High pressure
alarm
(Auxiliary) electric
heater protection
overheat alarm
too high
Condensate drain
hole blocked
Return gas temp.
sensor alarm
display insufficiency
REASONS
Water
temp.
sensor
circuit or short circuit.
Condenser coil temp.sensor
open circuit or short circuit.
Exhaust temp. sensor open
circuit or short circuit.
Ambient temp. sensor open
circuit or short circuit.
1.1. High pressure protection
switch off.
1.2. Ambient temp. too high or
water heat exchanger dirty
block.
2.1. Low pressure protection
switch off.
2.2. Leakage of refrigerant.
1. Electric heater protection
switch off.
2. Tank water temp. too high.
1. Lack of refrigerant.
2. Mix with air in system.
3. Lack of lubricating oil.
1.condensate pipe blocked;
2.Machine drain hole blocked;
Return gas temp. sensor open
circuit or short circuit.
1. No plug in power.
2. Mainboard and operation
panel communication break
off.
10
ERROR HANDLING
1. Check the water temp. sensor
open
connection.
2. Change the water temp. sensor.
1. Check the condenser coil temp.
sensor connection.
2. Change the coil sensor.
1. Check the exhaust temp. sensor
connection.
2. Change the exhaust temp. sensor.
1. Check the Ambient temp. sensor
connection.
2. Change the ambient temp. sensor.
1.1Check
or
change
pressure protector.
1.2. Check if the surround temp. is
too high, or clean the heat
exchanger of water tank.
2.1. Check or change the low
pressure protector.
2.2. Supply refrigerant and check if
there is any leakage.
1. Check if the water temp. is as LCD
display, or if water temp. is too
high.
2. Change the Electric heater.
1. Supply refrigerant.
2.
Re-vacuumizing,
refrigerant.
3. Change the lubricating oil of
compressor.
1.Check condensate pipe is blocked
or not.
2.Check machine drain hole is
blocked or not.
1.Check the Return gas temp.
sensor connection.
2. Change the ambient temp. sensor.
1. Check the power line and voltage.
2. Reconnect the line of
mainboard and operation panel.
3.
Change
the
operation panel.
the
high
and
fill
in
mainboard
or
V.3