Pump Set Up And Operations - Shop-Vac 92P Serie Manual Del Usuario

Ocultar thumbs Ver también para 92P Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Wet pick up accessories should be washed periodically; especially after picking up wet, sticky kitchen
accidents. This can be accomplished with a warm solution of soap and water.
FOAM SLEEVE
1. With the tank cover in an upside down position, slide the foam sleeve down over the lid cage, pulling
until foam sleeve completely covers the lid cage.
2. To clean the foam sleeve, side it up and off the lid cage. Shake excess debris off of the foam sleeve with
a rapid up and down movement.
3. Hold foam sleeve under running water for a couple minutes, rinsing from the inside of the filter. a water
wash is not always required, depending on the condition of the filter.
4. Check the filter for tears. If any are found, replace with a new filter.
PUMP SET UP AND OPERATION
WARNING
DISCHARGE STREAM AT UNIT!
WARNING
THE PUMP PICK UP ASSEMBLY.
NOTE: Not for use as a sump pump. Do not leave unit unattended while in use.
SET UP
1. The pump feature allows you to vacuum large amounts of liquid without having to manually empty
heavy tanks of liquid. Always disconnect the plug from the wall receptacle before removing the tank
cover. Remove the tank cover.
2. Remove any filters, other than foam sleeve, installed on the vacuum. If not already done, install foam
sleeve. Refer to the filter installation and maintenance section for installation instructions.
3. Remove ALL dirt and debris found in tank.
4. Insert tube into pick up cage and push until tube comes to a stop.
5. Take pick up assembly from step 4 and insert tube into hole in bottom of lid cage
and push until assembly comes to a stop. NOTE: Do not attempt to pump without
pick up cage in place or screen on pick up cage. Failure to do this could result in
damage to pump.
6. Replace tank cover and secure latches.
7. Remove outlet-fitting cap located on rear of tank cover. Connect a standard
garden hose onto outlet fitting. Then place other end of garden hose at suitable
drain. The garden hose is not included with your vacuum.
8. Attach the 2½" (6.4 cm) hose to inlet on front of tank.
9. Place wet pick up elbow on the hose end and attach desired accessory to elbow.
Elbow must be in place during pump operation. Do not attempt pump operation
without elbow in place. Do not cover bleed hole in elbow. Failure to follow these
precautions will result in overfilling of unit and misting through exhaust
port.
FILTER INSTALLATION AND
MAINTENANCE (CONT'D.)
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT DIRECT
THE CARTRIDGE FILTER IS NOT COMPATIBLE WHEN UTILIZING
PAGE 11