The lamp is automatically ignited as soon as the condensor microphone receives music signals.
Call up the internal program
In order to call up the internal program, set DIP-switches No. 9 and 10 to On.
Master/Slave-operation
Connect the master and slave-devices as desribed above and set the DIP-switches accordingly.
Please note: If you wish to change from one operating mode into another, you either have to switch off the
lamp/activate Blackout-mode or unplug the projector from the mains and plug it again.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
DMX-protocol
DMX-value
Feature
0-16
Offen/weiß
17-33
Red
34-50
Yellow
51-67
Magenta
68-84
Green
85-101
Orange
102-118
Blue
119-135
Pink
136-255
Rainbow effect with increasing speed
Control channel 2 - Dimmer intensity
DMX-value
Feature
0-255
Gradual adjustment of the dimmer intensity from 0 to 100 %
Control channel 3 - Shutter, strobe
DMX-value
Feature
0-14
Shutter closed
15-29
Open
30-250
Strobe-effect with increasing speed
251-255
Open
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
27/55
00026917.DOC, Version 1.4