ENGLISH
* Water supply pressure should be minimum 0.05 MPa (0.5 bar) and maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78
MPa (8 bar), use a proper pressure reducing valve. Do NOT throttle back the supply tap.
* A plumbing permit and services of a licensed plumber may be
required in some areas.
* The ice dispenser drain is gravity flow, so ensure drain hose has
an adequate pitch or fall.
* Drain lines should not be installed directly to the sewer system. A
vertical air gap of a minimum of 5 cm should be between the end
of the drain hoses from the ice dispenser and the floor drain.
* Be sure to use the new hose-sets supplied with the appliance.
Do not reuse any old hose-sets.
1) Attach the angled end of flexible inlet hose (accessory) to the
G3/4 fitting at the bottom of the ice dispenser as indicated,
ensuring rubber sealing washer is correctly positioned. Hand
tighten sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap, noting washer is correctly positioned
before hand tightening as above. It is a wise precaution to have a stop valve within easy
reach.
3) Attach the grey flexible drain hose (accessory) to the fitting at the bottom of the drain pan.
Use the hose clamp (accessory) to obtain a leak free joint.
II. OPERATING INSTRUCTIONS
Do not put your hands into the dispensing outlet. The icemaking mechanism may
suddenly move, resulting in injury.
All parts are factory-adjusted. Improper adjustments may result in failure.
If the unit is turned off, wait for at least 3 minutes before restarting the ice dispenser to prevent damage to the compressor.
Periods of 5 to 6 hours without dispensing ice could result in wet ice or an ice bridge forming in the storage bin. Always
turn off the ice making switch, and remove ice from the storage bin within 2 hours. Soggy and sticky ice should be removed
continuously as produced.
This ice dispenser is programmed to suspend ice dispensing action when the push lever/dispense switch is continuously pressed
for more than 2 minutes. Also, pressing and releasing the push lever/dispense switch repeatedly for extended periods may cause
the protector to stop the ice dispenser.
This ice dispenser is designed to produce edible ice. To keep the ice dispenser hygienic, follow the instructions in "III. 1.
CLEANING".
Water Supply
Inlet G3/4
Inlet Hose
CAUTION
NOTICE
HYGIENE
6
Hose Clamp
Drain Hose
Drain Outlet
5cm air gap
Drain
Water Supply Tap
Inlet Hose