Connecting The Piping - Friedrich M24CJ Manual De Instalación

Sistema split sin conductos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Burrs removal
1. Completely remove all burrs from the cut
cross section of pipe/tube.
2. While removing burrs put the end of the
copper tube/pipe in a downward direction
while removing burrs location is also
changed in order to avoid dropping burrs
into the tubing.
Putting nut on
- Remove flare nuts attached to indoor and
outdoor units, then put them on the pipe/tube
which have completed its burr removal.
(not possible to put them on after finishing
flare work)
Flare nut
Copper tube
Flaring work
1
Firmly hold copper pipe in a bar with the
dimension shown in table below.
2
Carry out flaring work with the flaring tool.
Outside diameter
mm
inch
Ø6.35
1/4"
Ø9.52
3/8"
Ø12.7
1/2"
Ø15.88
5/8"
A
Thickness
mm
mm
1.1~1.3
0.7
1.5~1.7
0.8
1.6~1.8
0.8
1.6~1.8
1.0
Bar
Bar
Copper pipe
Clamp handle
Check
1
Compare the flared work with the figures
given below.
2
If a flared section is defective, cut it off and
do flaring work again.
Smooth all round
Inside is shiny without scratches
Inclined
Even length
all round

Connecting the Piping

1
Pull the screw caps at the bottom of the
indoor unit
2
Remove the chassis cover from the unit by
loosing 3 screws
Chassis cover
11
Handle
Yoke
Cone
Red arrow mark
= Improper flaring =
Surface
Cracked Uneven
damaged
thickness

Publicidad

Tabla de contenido
loading

Tabla de contenido