3. Unscrew the cup assembly, remove outer
extension tube and set aside (see Figure 5).
4. Pull inner extension tube firmly away from cup
assembly to separate (see Figure 6), and set
aside.
5. Remove diaphragm from cup assembly (see
Figure 7) and inspect for foreign objects or
wear. Rinse thoroughly with clean water before
reinstalling. Replace diaphragm if necessary.
To reinstall the diaphragm:
1. Attach diaphragm to inner extension tube
(see Figure 8).
2. Insert inner pipe and diaphragm into cup
assembly. Align diaphragm tabs with notches
and pull straight through (do not twist) until the
edge of the diaphragm is visible
(see Figures 9 and 10).
|
Zodiac
T3
Pool Cleaner
Owner's Manual
®
®
Outer Extension
Tube
Cup Assembly
Notch
Tab
Cup Assembly
Edge of
Diaphragm
Figure 5
Figure 6
Figure 7
Figure 8
Diaphragm
Figure 9
Figure 10