Descargar Imprimir esta página

Quick TCD 1044 D Manual De Instalacion Y Uso página 23

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

To distinguish whether the signal concerns the bow or the stern of the boat they will be steadily lit, simultaneou-
sly with the flashing of the enablement LEDs, the green LED and the red LED of the involved part (bow or stern).
The resetting of this class of problems occurs, once the cause that has generated them has been removed, by
switching off and switching back on the remote control.
When problems 3, 4, 5 are present, it may be necessary to turn off and turn back on the external devices that
signalled the problem. Refer to their installation and use manual.
MAINTENANCE
The remote control needs no particular maintenance. To ensure optimum performance from the remote control,
once a year check the cables and the electrical connections.
Clean the remote control with a soft cloth dampened with water. Do not use chemical or abrasive products to
clean the remote control.
TECHNICAL DATA
MODEL
OUTPUT CHARACTERISTICS
Current capacity of right or left single thruster
commands.
INPUT CHARACTERISTICS
(1)
Supply voltage
(2)
Current absorption
Maximum current absorption
AMBIENT CHARACTERISTICS
Operating temperature
(4)
Protection rating
GENERAL
Dimensions including frame (L x L)
Weight
EMC class
(1)
With supply voltage less than 8 Vdc the remote control can reset.
(2)
Typical value with remote control disabled.
(3)
Typical value with remote control enabled and both joysticks activated.
(4)
Excluding the back of the remote control (IP20).
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) this device must accept any interference received including interference that may cause undesired operation.
®
QUICK
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
TCD1044 D - REV002B
MAINTENANCE - TECHNICAL DATA
(3)
TCD 1044
4A max
from 8 to 31 Vdc
10 mA
95 mA + absorption of the contactor coil
from -20 to +70 °C
IP 66
78 mm x 131 mm
250 g
EN 60945 - FCC Part 15 Rules 47
GB
23

Publicidad

loading