Installation: Electrical Wiring - Franklin Electric INLINE PRESSURE Serie El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION: ELECTRICAL WIRING

s
WARNING
!
or cause death.
s
CAUTION
!
Improper wiring can result in
permanent damage to the system. Pump connection must comply
with National Electric Code (NEC) or Canadian Electric Code (CEC)
and all applicable local codes.
s
WARNING
!
electrical connections, employ a competent electrician for the
installation. This ensures the installation complies with all noted
electrical codes.
s
!
Disconnect power at electrical panel before making any
electrical connections. Supply voltage must be +/- 10% of device
nameplate voltage.
s
!
Low or high voltage can damage the device and will void the
warranty. Connect device to dedicated branch circuit with no other
appliances on it.
s
!
A fused disconnect switch or circuit breaker should be placed at
or near the pump as required by local electrical codes.
s
NOTICE
!
Before installing the device, carefully check
the technical features and make sure they comply with those of the
pump and the system. The control label displays maximum pump hp.
Confirm compatibility between this device and the chosen pump.
s
NOTICE
!
Follow all indications on the electrical
diagram shown in Figure 5.
s
WARNING
!
result from failure to connect the pump and control to the service
entrance ground. Also ground metal plumbing and all other metal
near the device. When grounding these components, use a wire no
smaller than the power supply wires from the circuit breaker to the
device. To reduce the risk of electric shock, disconnect power before
working on or around the water system.
6
Hazardous voltage can shock, burn
If you are not sure of the proper
Serious or fatal electrical shock may
Installation Procedure: Wiring
1.
Disconnect electrical power at the main breaker.
2. Confirm the voltage rating matches the pump/motor's voltage
rating and that the device's hp/kW rating is equal to or greater
than that of the pump/motor.
3. Verify that the dedicated branch circuit for the device is
equipped with a proper listed fuse/listed circuit breaker.
4. Remove the cover of the device by removing the screws as
shown in Figure 4. Cover features and label may vary based
on your model.
Figure 4a
InlineSWC
Figure 4b
InlineSWP
Figure 4c
InlineADJ
Cover Screws
Cover Screws
Cover Screws

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Inline swcInline swpInline adj

Tabla de contenido