4. QuickTree® and Access Cover
®
®
Vertical discharge Pro-Series P370, P380 and P680 systems feature QuickTree
technology. The QuickTree
float system uses a
stainless steel mounting rod (tree) and specially designed cord clamping brackets to affix the pump float and (optional) alarm float in the
system. All floats are pre-set at the factory at optimum levels and do not require adjustment. NOTE: Field adjusting floats
may cause improper activation or turn-off of the pump and optional alarm.
®
®
QuickTree
removal and float inspection: The QuickTree
system is located under the separate access cover to help ease
®
inspection, service, and replacement of a float. To inspect the float(s), simply unbolt the access cover and lift out the QuickTree
assembly from its holder. There is no need to disconnect plumbing or remove the pump. Vertical discharge Pro-Series systems
feature a manual LE-series pump (with no switch attached directly to the pump). Operation of the pump is accomplished by the
®
QuickTree
system. Note: Side discharge Pro-Series systems are equipped with an automatic LE-series pump.
®
®
Re-inserting the QuickTree
: After service or inspection of the floats, re-insert the QuickTree
into its holder. Cords from the pump,
float switch and optional alarm need to be properly sealed as described below in the Integrated Cord Seal System.
Integrated Cord Seal System: It is important that cords from the pump motor, float switch and optional alarm float are sealed in the
specially designed rubber sealing channels under the access cover. Proper sealing is required to keep sewer gas from leaking from the
system. Place the cords securely in the rubber channels as shown in FIGURE B. being careful to remove excessive cord "slack" from
inside the system. IMPORTANT: Three cord channels are provided. For systems without the alarm option, only two channels will be
used and the third must be "plugged" with an attached rubber plug seal. SEE FIGURE C. If the alarm cord is present, all three
channels will be used. All rubber cover gaskets are permanently attached and do not require replacement.
®
IMPORTANT: Proper cord sealing – behind QuickTree
rod
RUBBER PLUG SEAL
6