Operation cont.
Resistance Measurements
WARNING:
Never test resistance on a live circuit.
1. Set the rotary function switch to
the
position
2. Press the MODE button until the
" " symbol appears on the LCD
display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
input jack.
4. Touch the test lead probes to the
component under test. If the component is installed
in a circuit, it is best to disconnect one side before
testing to eliminate interference with other devices.
5. Read the resistance in on the LCD display.
Continuity
WARNING:
Never test continuity on a live circuit.
1. Set the rotary function switch to
the
position.
2. Press the MODE button until
the " " symbol appears on the
LCD display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
input jack.
4. Touch the test lead probes to the
device or wire under test.
5. A beeper will sound if the resistance is approximately
50 or less and the resistance value will be shown
on the LCD display.
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG
LoZ mV AnF M k
AC+DC
0
10
20
AUTO HOLD REL PEAK MAX MIN AVG
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG
LoZ mV AnF M k
AC+DC
0
10
20
AUTO HOLD REL PEAK MAX MIN AVG
13
Operation cont.
Diode Test
WARNING:
30
40
50
60
1. Set the rotary function switch to the
2. Press the MODE button until the " " symbol appears
on the LCD display.
3. Insert the black test lead into the COM input jack and
the red test lead into the
4. Touch the test lead probes to the diode under test.
5. Forward voltage will indicate
0.4 to 0.7 on the display. Reverse
voltage will indicate "OL". Shorted
devices will indicate near 0 and
an open device will indicate "OL"
in both polarities.
Capacitance Measurements
WARNING:
taking capacitance measurements.
30
40
50
60
1. Set the rotary function switch to
the
position
2. Insert the black test lead into the
COM input jack and the red test
lead into the
3. Touch the test lead probes to
the capacitor under test.
4. Read the capacitance value on the
LCD display. It may take up to a
minute to get a stable reading on
large capacitors.
Never test diodes in a live circuit.
position.
input jack.
Red
Probe
Forward test
LoZ mV AnF M k
AC+DC
Safely discharge capacitors before
0
10
20
30
AUTO HOLD REL PEAK MAX MIN AVG
input jack.
14
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG
Black
Black
Red
Probe Probe
Probe
Reverse test
40
50
60
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG