4. Instructions to convert to a different type of gas

Important:
The adaptation for use another type of
gas, pressure or other power
corresponding adjustment, must be
performed by a qualified professional gas
company or manufacturer's
representative.
This cooktop is set for use with Natural
Gas, supply pressure of 20 mbar.
Use pressure regulators adequate to the
gas pressures indicated in the installation
instructions.
- If gas conversion injectors are not
included, get in touch with the After-
Sales Service and ask for them.

4.1 Replacing injectors

Important:
This operation shall be made by a
qualified professional, by the gas supplier
or by a manufacturer's representative.
(See injectors table under "Technical
characteristics").
Remove grids (A).
Remove burners (B).
Using a socket spanner of appropriate size
(C), unscrew the injector to be replaced.
Replace it with an injector suitable for the
new type of gas.
Reassemble the injector in (D).
If you have a multiple crown burner, use
side spanner to replace the injector (E).
Manual W10777748.indd 33
Manual W10777748.indd 33
- Adjust minimum supply.
Note:
If liquefied petroleum gas is used
(G30/G31), the minimum gas setting screw
must be tightened as far as it will go.
Important:
Any broken or destroyed security seal
must be replaced prior verification of
the correct installation and operation of
the devices.
Should you experience difficulty in
turning the burner knobs, please get in
touch with the After-Sales Service
for replacement.
Before installing the cooktop, affix the gas
calibration plate supplied with the injectors
so that it covers the existing information
relating to gas calibration.
B
C
E
D
33
A
F
02/09/15 09:23