Toshiba MMY-MAP0804HT5P Manual Del Propietário página 16

Ocultar thumbs Ver también para MMY-MAP0804HT5P:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

0001 - 0005
(Louver position
Louver No.
code)
* F1 appears in the CODE No. section on the
remote controller. This indicates that the louver
01 shown in the following figure is selected.
Electrical control box
03
Refrigerant
pipe
04
Drain pipe
01
NOTE
Even in louver lock mode, the louver temporarily
moves in the following cases:
When the air conditioner is stopped
When heating starts
When defrosting
When thermo. off.
29-EN
1114208801.indd 15
1114208801.indd 15
Releasing the louver lock
Set "0000" in Step 4 of "Setting the louver lock".
The
mark disappears.
* Steps 1 - 3 and 5, 6 of "Setting
the louver lock" also apply to
SET DATA
releasing the lock.
Adjusting the horizontal direction
1
Push and hold the
and "TEMP.
buttons for at least 4 seconds while running
is stopped.
blinks.
"01" appears in CODE No.
2
Push the
UNIT LOUVER
button (left side of the button)
to select a unit
The unit number changes each time you push the
button.
Unit No.
Unit No.
Unit No.
02
1-1
1-2
1-3
Unit No.
No display
1-4
The fan of the selected unit runs, and the louver
swings.
3
Push the "TEMP.
" buttons to
change the CODE No. to "45".
4
Push the "TIME
"buttons to select a
direction.
Direction SET
Direction setting
DATA
Smudging reduction position
"0000"
(reduces ceiling smudging)
(factory default)
Cold draft position
"0002"
(Less directly expose your body to
cool air)
5
Push the
button to check the settings.
The indicator stops blinking and stays lit, and the
settings are confirmed.
6
Push
button to finish the setting.
* If the cold draft position is selected, the ceiling
smudging reduction effect will be reduced.
– 15 –
4-way cassette type
When cooling
Point the louver horizontally.
0000
"
When heating
Point the louver downward.
The louver automatically closes when running is
stopped.
In pre-heating mode, the louver points upward.
The swing indication appears on the remote
controller even in pre-heating mode, but the actual
swing starts only after pre-heating is complete.
2-way and 3-way air discharge
The air discharge can be changed to the 2-way or 3-
way type to suit your room shape and style.
For details, contact the dealer where you purchased
the air conditioner.
2-way cassette type
When cooling
Point the louver horizontally to send cool air across the
entire room.
When heating
Point the louver downward to send heated air to the
floor.
1-way cassette type
(SH series)
When cooling
Point the louver horizontally to send cool air across the
entire room.
When heating
Point the louver downward to send heated air to the
floor.
The louver automatically closes when running is
stopped.
In pre-heating mode, the louver points upward.
The swing indication appears on the remote
controller even in pre-heating mode, but the actual
swing starts only after pre-heating is complete.
3/6/13 10:53 AM