Aluminium belt and silicone of
high temperature (300°C).
Pressure gauge.
Expansion vessel.
Buffer tank.
Electrolytic sleeve.
Flexible
hose
for
hydraulic
connection resistant to constant
temperatures of 110 °C
Ventillation grills.
"DIFLUX" piping.
4.11. Do not install the stove in a sleeping room.
4.12. Install a fire protection between the ground and the stove if the floor is a combustible material.
4.13. Security distances should be respected when the stove is installed in spaces where materials around it, be it
the construction material itself, the fuel or any other type of materials, are likely to be flammable. Ensuring a
better access to the stove for future maintenance or repair work is also worth considering.
A
Lateral wall.
Back of the stove. Minimum separation
B
that allows visualizing the label
marking the stove.
C
1.5 x depth of stove.
D
Shelf.
E
Depth of stove.
4.14. Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.15. The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove's output. It is mandatory to install at least
two metres in length vertically to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1 metre; greater lengths mean ash, condensation or corrosion
may build up in this area.
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is recommendable
to install an uninterruptible power supply (UPS) which we have available as an option. This apparatus only
feeds the exhaust vent.
RECOMMENDABLE
RECOMMENDABLE
OBLIGATORY
RECOMMENDABLE
RECOMMENDABLE
RECOMMENDABLE
OBLIGATORY
OBLIGATORY
LOCATION AND SAFETY DISTANCES.
≥ E
≥ 80 mm
See dimensions
≥ 400 mm
See dimensions
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
• If the pipe is not equipped with sealing rings
• To compare the pressure of the circuit with which
the boiler indicates.
• If the stove's expansion tank is not big enough
according to specific calculations.
• Installation of special features such as radiant
floor, areas operated by thermostatic valves,
other stoves working in the same site, etc. The
device must be fitted with a buffer tank for proper
regulation.
• Depending on the material used for the hydraulic
circuit.
•
SLIM and SLIM+ models.
•
Insert stoves.
•
AIRTIGHT INSTALLATION "DIFLUX" mounting.
34
D
A
Drawing 4