Grounding Fastener

The generator neutral is floating, which means that the AC
stator winding is isolated from the grounding fastener and
the AC receptacle ground pins. On a floating neutral
generator the AC receptacle ground pins are not functional.
Electrical devices, such as a GFCI, requiring a functioning AC
receptacle ground pin will not operate.
Special Requirements
There may be Federal, local codes, or ordinances that apply
to the intended use of the generator. Please consult a
qualified electrician, electrical inspector, or the local agency
having jurisdiction:
• This generator has a floating neutral and is not for use
on job sites requiring a bonded neutral.
8

Generator Location

Carbon Monoxide Poisoning
Operate this product ONLY outside far away from windows,
doors and vents to reduce the risk of carbon monoxide gas
from accumulating and potentially being drawn towards
occupied spaces. Install/maintain battery-operated carbon
monoxide alarms or plug-in carbon monoxide alarms with
battery back-up according to the manufacturer's instructions.
DO NOT run this product inside homes, garages, basements,
crawlspaces, sheds, or other partially-enclosed spaces even
if using fans or opening doors and windows for ventilation.
ALWAYS place this product downwind and point the engine
exhaust away from occupied spaces.
Risk of Fire Clearances
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank
causing a fire, resulting in death, serious injury
and/or property damage.
• Keep at least 5 ft. (1.5 m) clearance on all sides of generator
including overhead.
www.powerboss-equipment.com
Exhaust Port
Pointed away from
occupied spaces