Descargar Imprimir esta página

Wiring - Honeywell RTH7600 Serie Instrucciones Para La Instalación

Termostato programable
Ocultar thumbs Ver también para RTH7600 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Wiring—conventional system
About your new thermostat
Alternate wiring (conventional systems)
If labels do not match terminals, connect wires as
shown here (see notes, below).
Remove metal jumper connecting R and Rc only
if you must connect both R and Rc wires.
If your old thermostat had both R and RH wires,
remove metal jumper. Connect the R wire to the
Rc terminal, and the RH wire to the R terminal.
If your old thermostat had only 1 C or C1
wire, connect it to the C terminal. If your old
thermostat had 2 C or C1 wires, wrap each
separately with electrical tape and do not
connect them.
RC
R
W
Y
G
C
Y2
W2
Rc
2
R
W
Y
G
C
Y2
W2
21
69-2206ES—05
RTH7600
2
3
M28076

Publicidad