Operational Mode; User-Maintenance Instructions - Campbell Hausfeld Tl050189 Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

opERaTinG insTRUCTions
(Continued)

opERaTional MoDE

To remove nuts, turn the forward/
reverse dial to the right . To install nuts,
turn the forward/reverse dial to the left .
Reverse the procedure if the threads
are left-handed . Do not overtighten the
nuts .
When tightening,
do not torque
down the nuts or bolts with the
ratchet as typically done with a
hand wrench. This can damage
the tool by breaking parts in the
ratchet mechanism.
Use of a whip
hose prevents
accidental triggering of the tool
when pressurized air is connected
to the system.
In addition, the tool's vibration wears
out quick couplers prematurely .
Using fittings or air hoses which are too
small can create a pressure drop and
reduce the power of the tool . A 3/8 inch
(I .D .) fitting with 1/4 inch NPT threads
is recommended . Most compressors
are shipped with a short, 1/4 inch I .D .
hose . For proper performance and more
convenience, use a 3/8 inch I .D . hose .
Hoses longer than 50 feet should have a
1/2 inch I .D .
noTE: It is not recommended to install
a quick coupler between the air tool
and the leader (whip) hose .
Never carry a tool
by the hose or
pull the hose to move the tool or a
compressor. Keep hoses away from
heat, oil and sharp edges. Replace
any hose that is damaged, weak or
worn.
UsER-MainTEnanCE
insTRUCTions
TECHniCal sERviCE
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual .
REplaCEMEnT paRTs infoRMaTion
For information regarding where to
order replacement parts, call toll free
1-800-543-6400 . Please provide the
following information:
• Model number
• Stamped code
• Part number and description
Tool REpaiR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently .
5
assEMblY pRoCEDURE foR sEals
When repairing a tool, the internal
parts must be cleaned and lubricated .
Parker O-lube or equivalent must be
used on all o-rings . Each o-ring must be
coated with O-lube before assembling .
A small amount of oil must be used on
all moving surfaces and pivots . After
reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing .
sToRaGE
The air tool must be lubricated before
storing . Follow the air tool lubrication
instructions with an exception to step 4 .
Only run the air tool for 2 to 3 seconds
instead of 7 to 10 seconds because more
oil needs to remain in the air tool when
storing .
www.chpower.com
Tl050189

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido