T o keep t h e lamp o f f , turn o f f t h e lamp status. F irst pull
an d release t h e s w it c h trigger. A n d t h en press t h e but-
ton
f or one se c on d w it h in 1 0 se c on d s.
T o turn on t h e lamp status again, press t h e button again
similarly.
NOTE: To confirm the lamp status, pull the trigger.
When the lamp lights up by pulling the switch trigger,
t h e lamp status is O N. W h en t h e lamp d oes not c ome
on, t h e lamp status is O F F .
NOTE: When the tool is overheated, the light flashes
for one minute, and then the LED display goes off. In
t h is c ase, c ool d o w n t h e tool be f ore operating again.
NOTE: Use a dry cloth to wipe the dirt off the lens of
t h e lamp. Be c are f ul not to s c rat c h t h e lens o f lamp, or
it may lower the illumination.
Changing the impact force
Fig.7: 1. H ar d 2. S o f t 3. R e v erse rotation auto stop
mo d e 4. C h ange d in t h ree steps 5. Button
The function of Reverse rotation auto stop mode works only with pulling the trigger fully in counterclockwise tool
rotation. W h en t h e bolt / nut gets enoug h loosene d , t h e tool stops t h e impa c t an d rotation.
For approximately one minute after releasing the switch trigger, the impact force can be changed.
Impact force grade displayed
on panel
H ard
S of t
R ev erse rotation auto stop
mod e
NOTE: Reverse rotation auto stop mode is available only when the tool rotates counterclockwise. When rotating
c lo c k w ise in R e v erse rotation auto stop mo d e, t h e impa c t f or c e an d spee d are t h e same as H ar d impa c t mo d e.
NOTE: When all lamps on the switch panel go out, the tool is turned off to save the battery power. The impact force
grade can be checked by pulling the switch trigger to the extent that the tool does not operate.
NOTE: W h ile pulling t h e s w it c h trigger, t h e impa c t f or c e gra d e c annot be c h ange d .
Maximum blows
(/min)
-1
3,6 00 min
T igh tening w h en f orc e and
speed are d esired .
(/min)
Tightening when you need fine
-1
2,000 min
adjustment with small diameter
bolt.
(/min)
-1
3,6 00 min
L oosening w ith auto stop
f unc tion.
7 ENGLISH
Reversing switch action
Fig.6: 1. R e v ersing s w it c h le v er
CAUTION:
Always check the direction of
rotation before operation.
CAUTION:
Use the reversing switch only after
the tool comes to a complete stop. C h anging t h e
direction of rotation before the tool stops may dam-
age t h e tool.
CAUTION:
When not operating the tool,
always set the reversing switch lever to the neu-
tral position.
T h is tool h as a re v ersing s w it c h to c h ange t h e d ire c tion
o f rotation. D epress t h e re v ersing s w it c h le v er f rom t h e
A si d e f or c lo c k w ise rotation or f rom t h e B si d e f or c oun-
ter c lo c k w ise rotation.
W h en t h e re v ersing s w it c h le v er is in t h e neutral posi-
tion, t h e s w it c h trigger c annot be pulle d .
Y ou c an c h ange t h e impa c t f or c e in t h ree steps : h ar d ,
so f t, an d R e v erse rotation auto stop mo d e.
T h is allo w s a tig h tening suitable to t h e w ork.
Every time the button is pressed, the number of blows
c h anges in t h ree steps.
Purpose
Example of application
A ssembling steel f rames.
A ssembling f urniture.
D isassembling bolts/ nuts.