1. INTRODUCTION
This instruction manual has been drafted
in accordance with the requirements of the
Machinery Directive CE 2006/42/EG. The
instruction manual is an integral part of the
lifting tower to be consulted before, during
and after tower's start-up, likewise whenever
deemed necessary, respecting the contents
for each and all the parts thereof.
This is the only way to achieve the basic ob-
jectives established in the manual's base such
as preventing accident risks and the maxi-
mum possible optimisation for the lifting
tower features.
This manual has taken extreme care regar-
ding safety and accident prevention at work
while using the machine, highlighting infor-
mation of particular interest to the user.
ATTENTION: BEFORE TO USING THE
LIFTING TOWER,
READ THIS MANUAL CAREFULLY
2. GENERAL DATA
2.1. Technical Data:
Name: LIFTING TOWER
Model: AT-06
Technical characteristics:
Maximum height: 6,50m.
Minimum height: 1,97m.
Maximum load: 250kg.
Minimum load: 25kg.
Material: Aluminium AL Si 6082 / T6.
Open base area: 1,66 x 1,72m.
Closed base area: 0,48 x 0,48m.
Weight: 107kg.
Winch: 900kg maximum load with automa-
tic load retention brake.
Cable: Galvanized steel under EN 12385-4.
Cable maximum load: 2.000kg.
Cable torsion resistance: 1.770N/mm².
Cable diameter: 6mm.
Cable composition: 6x19+1.
Fixation of tower sections to working height
with safety pins.
Leg anchorage with safety pins.
Bubble level to adjust tower's vertical posi-
tion.
Equipment description:
Lifting tower AT-06 has been designed to
vertically raise structures and lighting and
sound equipment to different heights.
Tested by skilled personnel having passed all
the operating, maximum load and dimen-
sion inspections.
Company: FENIX Stage, S.L.
Address: Avda. de los Trabajadores, 24
Horno de Alcedo - 46026 - Valencia (Spain)
2.2. Applicable regulations
- Machinery Directive CE 2006/42/EG.
- BGV C1 (GUV 6.175).
- BGG 912 (GUV 66.15, GUV G-912).
- EN 12385-4:2008-06.
- DIN EN 10305-3:2010-05.
www.audiovias.com
ENGLISH
11 11