Dear customer,
We thank you and congratulate you on your choice. The Steri-
Natural 2in1 modular electric steam steriliser adapts itself to the
items to be disinfected occupying a small space in the kitchen
thanks to the two configurations available: FULL SIZE and COM-
PACT.
It disinfects safely and securely with pure natural steam and no
chemical substances, making it extremely convenient and easy
to use. The 2 configurations are compatible with all Chicco feed-
ing bottles and breast pumps (the parts that can be subjected to
hot sterilisation) and most of the other brands of feeding bottles
and breast pumps on the market. Easy to use, it can contain up
to six 330 ml/11 oz feeding bottles of all Chicco lines with the
relative accessories (cap rings, teats and cups) in the FULL SIZE
configuration, and up to two 330 ml/11 oz feeding bottles with
the relative accessories for the COMPACT configuration.
The number of feeding bottles of brands other than Chicco that
can be placed in the appliance may be lower than that indicated
here.
Please read these instructions carefully before use and keep
them for future reference.
DESCRIPTION (fig. 1)
a) Cover
b) Rack unit
c) Motor body
d) Base
e) Heating plate / container
f ) Appliance power cord with plug
g) Cycle start switch*
g1) pilot light indicating that the appliance is in use
h) Main ON/OFF switch
*WARNING: the cycle start switch is not an OFF button.
To switch the appliance OFF and/or stop the sterilising
cycle, simply press the main ON/OFF switch (g).
INSTRUCTIONS FOR USE
SETTING UP THE CONFIGURATIONS OF THE STERILISER
The steriliser can be assembled for use in two different configu-
rations: FULL SIZE and COMPACT.
1) FULL SIZE (fig. 2)
For disinfecting up to six 330 ml/11 oz feeding bottles of all the
Chicco lines with the relative accessories.
It is assembled by placing the following components one on top
of another in order on the base of the appliance (d): motor body
(c), rack unit (b) and lid (a).
2) COMPACT (fig. 3)
For disinfecting up to two 330 ml/11 oz feeding bottles of all the
Chicco lines with the relative accessories or other small objects,
such as soothers.
It is assembled by placing the following components one on top
of another in order on the base of the appliance (d): rack unit
(b) and lid (a).
HOW TO PREPARE AND USE THE APPLIANCE
Always carefully wash and rinse the objects to be disinfected be-
fore placing them inside the steriliser.
Disinfecting TEATS:
- To reduce the risk of contaminating the teats with your fingers
after sterilising them, it is recommended to fit them on the cap
ring before placing them in the rack (b).
- Place the cups above the teats fitted on the cap rings in a slight-
ly sloping position to allow the steam to enter the cups.
Disinfecting FEEDING BOTTLES:
- In the FULL SIZE configuration: Place up to six 330 ml/11 oz
feeding bottles of all the Chicco lines inside the motor body (c)
in a vertical position with the neck facing down and the relative
accessories in the rack unit (b).
- In the COMPACT configuration: Place up to two 330 ml/11 oz
feeding bottles in a horizontal position, taking care not to ob-
struct the mouth of the bottle with the accessories so that steam
can enter them freely.
WARNING: check that the accessories placed in the rack
unit (b) do not prevent the lid from being closed prop-
erly (a).
Before you use the appliance for the first time, always perform
an empty sterilising cycle with no feeding bottles or other ac-
cessories inside.
During the first disinfecting cycles, the appliance could release
a slight odour. This is not a sign of malfunction or damage and
should be considered absolutely normal.
WARNING: When using the appliance for the first time, as
soon as the main ON/OFF switch is turned on (h), the
appliance could begin warming up immediately without
you having pressed the cycle start switch (g) on the front. This is
normal.
1) Always place the appliance out of reach of children, on flat,
level surfaces that are not sensitive to heat and/or humidity, and
close to a mains socket that is easily accessible.
2) Remove the lid (a), rack unit (b) and motor body (c) (fig. 4).
3) Place water in the heating plate/container (e) up to the water
level mark indicated (fig. 5)
· Use in the FULL SIZE configuration: 120 ml
· Use in the COMPACT configuration: 80 ml
NB: The use of distilled water considerably reduces the formation
of limescale on the heating plate.
4) Assemble the steriliser in the configuration you require (for
assembly instructions please see the section "Setting up the con-
figurations of the steriliser").
5) Place the objects to be disinfected inside the appliance (see
the first paragraph of this section).
6) Connect the power cable plug (f ) to the mains socket.
7) Start the appliance by moving the main ON/OFF switch (h) to
l (ON), then press the cycle start switch (g); When the pilot light
(g1) comes on, the appliance is heating up the water.
NB: Sterilises in just 5 minutes warming time excluded.
8) After completing the sterilising cycle, the appliance will switch
off automatically. Switch the appliance off by moving the main
ON/OFF switch (h) to 0 (OFF) and disconnect the power cable
plug (f ) from the mains socket.
9) Wait a few minutes before removing the disinfected objects
from the appliance, again taking maximum care to prevent any
boiling steam and drops of extremely hot water from leaking out
and causing burns.
Always wash your hands thoroughly before touching the steri-
lised objects.
10) Before starting a new sterilisation cycle, always wait until the
appliance has completely cooled down.
In both configurations, FULL SIZE and COMPACT, the time of the
sterilisation cycle may vary depending on the number, size and
type of feeding bottles and accessories sterilised and the quan-
tity of water placed inside the heating plate/container (e).
NB: disinfected items will remain sterile inside the steriliser with
the lid (a) on for about 24 hours. If the lid (a) is removed during or
after use, the disinfection status will be interrupted.

CLEANING AND MAINTENANCE

1. Allow the appliance to cool down before handling it.
12