Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
5) Should dirty residue remain in the evaporation pan,
pour some clean, fresh water into the base unit and
empty it out via the side edge.
7) Reinsert the anti-lime pad and position the air outlet back on the base unit.
Rinsing the water tank, replacing the water
• Clean the water tank regularly, at least once a week if using daily.
• Use a mild cleaning product or vinegar/vinegar-based cleaner.
• Clean the thread of the screwed plug using the brush.
• Fill the water tank halfway with water.
• Tightly close the water tank using the screwed plug.
• Shake the water tank by rocking it back and forth several times.
• Empty out the water completely.
• Repeat the process using clean, fresh water.
Clean the air humidifier inside and out
• Empty the water from the base unit via the side edge.
• Wipe the air humidifier with a damp cloth inside and out.
Only use a mild flushing agent or vinegar/vinegar-based cleaner to perform cleaning work.
Descaling
Descaling the ultrasound membrane
Hard water can cause limescale to build up in the device and especially on the ultrasound membrane. This
forms white deposits. Descale the device regularly.
• Drop some descaler onto the ultrasound membrane.
• Leave it to take effect for two to five minutes.
• Clean the ultrasound membrane using the cleaning brush.
• Rinse the base unit twice with clean, fresh water.
Cleaning inside the base unit
• Dip a damp, soft cloth briefly in descaling solution.
• Use the cloth to wipe the inside of the base unit.
• Carefully pour some clean, fresh water into the base unit.
• Empty the water from the base unit via the side edge.
• Repeat the process using clean, fresh water.
6) Rinse the anti-lime pad in clear water.