Descargar Imprimir esta página

Comunello Automation QUAD-230V-HP Instrucciones De Uso Y De Instalacion página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EAGLE- connection diagram of the motors
5.4
DELAY OF THE MOTOR no.2
1
SW1
ON
1
2
2
DELAY
MOTORS
MOT 2
DELAY OF THE MOTOR no.1
1
SW1
ON
1
2
2
DELAY
MOTOR
MOT. 1
Wire connection of the motors (version without encoder) to the control unit:
Configuration - MOTOR NO.1 ON THE LEFT, MOTOR NO.2 ON THE Rights
MOTORE n.1 (LEFT)
NERO in OP1
BLU in CM1
BROWN on CL1-
CN1
DIP1 ON = 2 motors configuration
DIP2 OFF = Delay of motor no. 2
DIP1 ON = 2 motors configuration
DIP2 ON = Delay of motor no. 1
SW2
ON
1
2
INV
INV
OFF
MOT 2
SW2
ON
1
2
INV
INV
OFF
MOT. 2
MOTORE n.2 (Rights)
BLACK with OP2
BLUE on CM2
BROWN on CL2
COMUNELLO ®Copyright 2021 - All rights reserved
2
DIP1 OFF = inversion MOTOR no.
1 disabled
DIP2 ON = inversion MOTOR no. 2
enabled
2
DIP1 ON = 2 motors configuration
DIP2 OFF = Delay of motor no. 2