Important notes:
- In the presence of limit switches connected to the control unit, the detection of the obstacle always causes the reversal of the
closing movement and the inversion for 2 seconds in opening.
- The detection of an obstacle causes the brief inversion of movement in closure and opening.
- In the absence of limit switches connected to the control unit, detection of an obstacle will always cause a brief inversion of
direction except in the last 5 seconds of the manoeuvre, in which case a stop will be made.
7.3.6 - BLACK-OUT
In the case of a black-out and subsequent restoration of the power supply, the first manoeuvre will be in opening with a fixed speed as
set by the trimmer "SLOWING"; when a mechanical block is encountered, in the absence of an electrical limit switch, the doors will not be
obstructed, but will execute a STOP (version with encoder). With a subsequent command, the doors will close again at reduced speed
until completely closed. The next manoeuvre will be at the speeds set by the trimmers.
8 DETAILED DESCRIPTION OF THE PROGRAMMING
PROGRAMMING:
SELECT key: it determines the type of function to be memorized, as indicated by the blinking of the LED.
By pressing the key several times, it is possible to scroll the menu and move to the desired function. The selection remains active for 10
seconds, displayed by the flashing LED; when this interval elapses, the control unit exits programming.
SET key: it confirms and changes the programming according to the type of function determined by the SELECT key.
Following confirmation, the respective LED remains on / off for about 2 sec. and then starts flashing again.
Important notes: the function of the SET key can also be replaced by the remote control if previously programmed (LED L2 CODE TX lit).
Programming enabled only with the closure of N.C contacts enabled.
MAIN MENU
8.1
L1
STEP BY STEP
L2
CODE TX
L3
CONDO
L4
MOTOR TIME
L5
PAUSE TIME
L6
DELAY
L7
PRG AUTOM
LEV
MENÙ
LED L1
8.1.1
- STEP BY STEP or OPEN-CLOSE:
Programming
In the default configuration the control unit is set with "Step-By-Step" operating logic enabled (LED no.1 ON);
if the "Automatic Open-Close" operating logic is required (LED no.2 OFF), proceed as follows:
• By the key SELECT, position yourself on the blinking LED no.1;
• Press the SET key;
• The LED L1 turns off and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
LED L2
8.1.1
- CODE TX:
CODE TX: Remote controls storage
Up to 120 remotes with different codes of either the fixed or the rolling code type can be saved on the control unit
Remote control code programming of the total opening (Mot. no. 1 + Mot. no.2):
• By the key SELECT, position yourself on the blinking LED 2 "CODE TX";
• Press key SET once to memorize the PP channel;
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that programming has been completed;
• The LED L2 starts to blink again to indicate that you have 10 additional sec. to store a new code;
• On expiry of those 10 sec.the LED L2 will remain steady on.
Remote control code programming of the partial / pedestrian opening (Mot. no. 1):
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET twice to memorize the PPED channel and the led will modify its blinking (110110110);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that programming has been completed. The extra time of 10 sec. to
store a new PPED channel is then preview as for the PP channel.
COMUNELLO ®Copyright 2021 - All rights reserved
46
Step-by-step
Remote control stored
ON
Complete stroke stored
With automatic closure
ON
ON
ON
Automatic (Open-Close)
No remote control stored
OFF
30 s. (no slowdowns)
OFF
OFF
OFF