• If a previously saved pedestrian code is transmitted continuously the control unit will enter programming mode of a new pedestrian
code and LED L2 will blink as though acquisition of the pedestrian code were active (1 1 0 1 1 0 1 1 0);
• If the code is associated with the 2nd CH/AUX input the LED will blink as though acquisition of the 2nd CH code were active (1 1
1 0 1 1 1 0 1 1 1 0).
To enable the remote programming function, proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• Press the SET key;
• LED L7 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
EXTENDED MENU 3
8.4
The control unit is factory set to allow direct selection exclusively of the main menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed as follows:
• Select blinking LEV LED
• press SET 3 times
• The led will start blinking (alternate flashing of the LEV LED
There will be 30 seconds to select the functions of the Extended Menu 3 using the SELECT and SET keys; once an additional 30 seconds
have elapsed the control unit reverts to the main menu.
ID
REFERENCE LED
L1
SOFT STOP
L2
SOFT START
L3
RELEASE STROKE
L4
SLAM LOCK
L5
ELS / CMD PED
L6
LAMP / L.CORT / INDICATOR L
L7
PRELAMP / LAMP IN PAUSE
LEV
MENU LEVEL
LED L1
8.4.1
- SOFT STOP:
The control unit is supplied by the manufacturer with the Soft Stop function disabled. To enable the function, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
In this way, during door movement, when a PP/DS1/DS2/DS3 command is sent, the speed will gradually be brought to zero (within 2
seconds).
Repeat the procedure if you wish to restore the previous configuration.
Notes:
- Soft-stop is not operated when a limit switch is triggered, when the Stop / safety edge button is activated and in case of an
obstacle.
LED L2
8.4.2
- SOFT START:
The control unit is supplied by factory with the Soft Start function disabled. With this function enabled at the beginning of the movement the
speed gradually increase from the minimum to the value set by the "SPEED" trimmer during the first 2 seconds of operation.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L2;
• LED L2 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
Important note: when the Soft Start function is enabled, the control unit automatically disables the Starting Torque function, while if Soft
Start is disabled then Starting Torque is automatically enabled.
LED L3
8.4.3
- RELEASE STROKE (in opening phase):
The control unit is supplied by factory with the release stroke function disabled. This function consists of sending a closing command for
2 seconds before starting the opening stroke: in this way the release of the lock is facilitated to allow the correct execution of the opening
phase. Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
COMUNELLO ®Copyright 2021 - All rights reserved
52
ON
ON
ON
ON
ON
ON
ON
3 FLASHING
).
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Publicidad

loading

Productos relacionados para Comunello Automation QUAD-230V-HP