Descargar Imprimir esta página

Comunello Automation QUAD-230V-HP Instrucciones De Uso Y De Instalacion página 20

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• Press the SET key;
• Wait for a time equivalent to the desired time interval (from 1 sec. up to 4 min.);
• Press the SET key again momentarily and at the same time the automatic closing time will be saved and LED L5 will remain steady
on;
If you wish to restore the initial condition (no automatic closing)
• select blinking LED L6.
• press the SET key twice consecutively in a time period of 2 seconds.
• The LED will switch off and the operation will be completed.
During programming, instead of the SET key on the control unit you can use the button on the remote, providing the remote has been
saved beforehand.
LED L6
8.1.6
- LEAVES DELAY:
The control unit is factory set with 4 Sec. leaves opening and closing delay. Proceed as follows if you wish to modify that period:
• By the key SELECT, position yourself on the blinking LED L6;
• Press the SET key;
• Wait for a time equivalent to the desired time interval for leaves delay in the closing phase (from 4 sec. up to 15 min.);
• Press the SET button again for an instant, thus determining the door delay time to be memorised (during opening it is fixed at 4
seconds, whereas it will be the gate delay closing time for the programmed time);
• LED L6 becomes steady on and programming will be completed: the delay time is fixed for opening leaves at 4 sec and it is up
to 15 sec for closing leaves
If you want to deactivate this function (without leaves delay),
• select blinking LED L6
• press the SET key twice consecutively in a time interval of 2 seconds, at the same time the LED will switch off and the operation
will be terminated.
LED L7
8.1.7
- AUTOMATIC PROGRAMMING:
The control unit allows to carry out an Automatic Programming (SIMPLIFIED and only in the presence of encoders and / or electric limit
switches) to automatically adjust stroke and slowdowns of the leaves. To set a new stroke, programming must be carried out with leaves
in intermediate position (partially open) as follows:
• Position the actuators manually until half of the stroke before continuing.
• By the key SELECT, position yourself on the blinking LED no.7;
• Press the SET key;
• To determine its zero position, Motor no.2 performs its closure until it reaches the limit switch or mechanical stop;
• Afterwards the same operation will be repeated by the Motor no. 1;
• The control unit executes the Auto programming procedure by performing a complete opening and closing cycle and the
Deceleration cycle is set automatically too at approximately 15% of the complete cycle;
• Press the SET button to memorize the motor stroke.
During Automatic Programming, instead of the SET key on the control unit you can use the button on the remote, providing the remote
has been saved beforehand.
Important notes:
- In the event that the motors move in a manner other than that described:
• Disconnect the power supply to the control unit.
• Change the position of Dip Switch SW2 to change the drive direction to the desired motor without physically using the electrical
connections.
- During Automatic Programming, the radio control button (if previously memorised) may be used instead of the control unit SET
button.
- It is not possible to carry out Automatic Programming in the absence of limit switches and/or encoders wired to the control unit.