7.2.13 - ELECTRIC LOCK CONTROL OUTPUT:
The control unit features an output to control a 24V DC 15W max. electric lock. The command is switched on at each initial opening
movement for a period of 2 seconds.
DIP-SWITCHES AND TRIMMERS ADJUSMENTS
7.3
Important Note: change the settings of dip-switches SW1 and SW2 with the control unit off and only subsequently repeat the control unit
programming procedure.
7.3.1 - MOTOR 1 OR MOTOR 2 DELAY CONTROL AND ENABLING OF 1 OR 2 MOTORS
Important note: in the case of 1 motor operation (Dip Switch 1 of SW1 set in OFF position), Dip Switch 2 of SW1 must be set in OFF
position, otherwise SW2 is disabled.
The electronic control unit is equipped with a dip-switch SW1 that is used to select operation with 1 or 2 motors and to define which of the
two starts first and which starts second.
7.3.2 - MOTOR 1 AND MOTOR 2 STROKE DIRECTION
The electronic control unit is equipped with dip-switches that can be used to change the stroke direction of each connected motor without
rewiring the electrical connections: dip-switch 1 controls Motor 1 while dip-switch 2 controls Motor 2.
7.3.3 - DECELERATION (SLOWING):
The motor deceleration function is used in the gates to prevent the mobile doors from striking at high speed at the end of opening and
closure.
When programming the Motor Time, the control unit also allows deceleration to be programmed in the desired points (before total opening
and closure). Moreover, through the "SLOWING" trimmer it is possible to choose from three deceleration speed values.
7.3.4 - REGULATION OF MOTOR POWER (FORCE):
The electronic control unit is equipped with a "SPEED" trimmer for adjustment of the speed delivered by the Motors, completely managed
by the microprocessor.
Adjustment can be performed in a range between 50% and 100% of maximum speed.
Initial starting torque can be set for each movement by feeding the operator at full power for 2 seconds, even if operator speed control is
enabled.
Important notes:
- Initial starting torque is disabled automatically if the Soft Start function is enabled (see section 8.4.2.);
- A variation of the trimmer "SLOWING" requires the repetition of the learning procedure, since the times of manoeuvre and slowing
may vary.
7.3.5 - OBSTACLE DETECTION (ONLY IN VERSION WITH ENCODER):
The electronic control unit is equipped with a "SENS" trimmer, completely managed by the microprocessor, for adjustment of the opposing
Force required to detect the presence of an obstacle. The adjustment can be made with a trip time from a minimum of 0.1 seconds to a
maximum of 10 seconds
ATTENTION: with the sensitivity set at the minimum level, it is recommended to install a safety edge.
SW1
SW1
ON
ON
1
2
1
1
NOT
2
MOTOR
CONSID.
MOTORS
SW2
SW2
ON
ON
1
2
1
2
INV
INV
INV
INV
OFF
OFF
MOT 1
OFF
SW1
ON
2
1
2
MOTOR
2
MOTOR
MOTORS
1 DELAY
2 DELAY
SW2
SW2
ON
ON
1
2
1
2
INV
INV
INV
INV
OFF
MOT 2
MOT 1
MOT 2