11 Reactivation (Refreshing of sulphated or rather deeply discharged
batteries)
12 Setup
After selecting the Setup the following settings can be customized.
- Date
- Time of day
- Charging voltage EASY CHARGE
- Charging voltage BOOST
- Charging voltage CHARGE+TEST
- Charging voltage SERVICE
- Adress date for the battery-test-
protocols
Of pressing the respective button can be changed the value.
The charging voltage can range from 13,6V to 15,0V and the
SERVICE-voltage can be adjusted from 13,3V to 14,5V.
In the 24V or 6V mode apply the respective double / half values of 12V settings.
The charge level EASY-CHARGING is
used to charge lead-acid batteries
without any further charge settings are
necessary. Die Batterie wird mit maximal
The battery is charged with a maximum
charge current 30 A (6V 5A, 24V 20A)
and is suitable for batteries between 30
Ah-150Ah. After selecting EASY-
CHARGING and when the device is
correctly connected to the battery to be
charged.
After selecting EASY-Charge you have to
select the charging voltage from the
battery to be charged in the following
menu.
After correct connecting the battery to be
charged appears in the left battery
SETUP
EASY CHARGE (12V + 24V)