Berner BHFL75 Instrucciones De Empleo página 22

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

previously fully discharged battery less than 50% on the battery printed rated
capacity may be assumed that the battery is approaching end of life.
Is the charged capacity significantly larger (> 130%) of the printed battery capacity
and isn't reducing the charging current over several hours then the battery have to
be examined on a cell short out.
The charging process can be interrupted at any time by pressing the "Stop" button
and affirmation of the confirmation message and the display switches to the main
menu. By pulling the plug from the wall outlet, the charger is also turned off.
Before removing the battery cables you always have to finish the charging to avoid
sparking when the deducting the charging clips.
When you interrupt charging of a battery mounted in a vehicle must always first the
battery cable removed from the chassis and only then the other battery cable.
BOOST CHARGE (12V + 24V)
The charging stage BOOST CHARGE is used for fast initially charging of lead
batteries. The battery is charged with the maximum charging current of up to 70 A
(6V-10A or 24V-35A). It is important to ensure that the battery not becomes hot
when the battery charging with the Boost function!
If the battery gets too hot, stop BOOST CHARGE and select EASY CHARGE
because the battery is apparently unable to save the high current.
The battery should have at least a rated capacity of 50Ah.
All functions and display options are analogous to the EASY-CHARGE function.
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

329145

Tabla de contenido