Descargar Imprimir esta página

Bürkle UniSampler Instrucciones Para El Uso página 4

Ocultar thumbs Ver también para UniSampler:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
English
General safety requirements
`
`
Read these directions for use carefully before using.
`
`
Keep these directions for use where they will be
accessible for all users.
`
`
Failure to comply with the directions for use shall
render all warranty conditions null and void and
may lead to personal injury and material damage.
`
`
The instrument must only be used by qualified
skilled employees.
Safety instructions before using
`
`
Follow the manufacturer's instructions and safety
instructions of the medium you are sampling.
`
`
Damage to the respiratory tract and other organs
due to off-gassing media. Use in ventilated rooms or
under a suitable exhaust hood.
`
`
The instrument is not suitable for sampling aggressi-
ve or highly flammable/explosive liquids.
CAUTION!
Liquid entering the instrument due to overfilling
or tipping. Bodily injury due to escaping liquid and
damage to the instrument.
`
`
Shut down and secure the instrument immedi-
ately.
`
`
Contact the dealer or manufacturer.
Safety instructions during and after use
`
`
The instrument must only be used within the
confines of applicable material resistance and for its
designated purpose. Any other type of use will affect
the warranty/guarantee.
`
`
The instrument is not suitable for cleaning in a
dishwasher.
Layout and function
The instrument is made of non-conductive material and
is suitable for filling non-aggressive, non-combustible
liquids. The instrument is maintenance-free.
Scope of delivery
1 x
Vacuum pump
1 x
Suction hose (PVC, 2,50 m)
1 x
Suction hose (PVC, 1,00 m)
1 x
Sampling bottle (PP, 1000 ml)
1 x
Universal adapter for sample bottles (PVC)
1 x
Hose weight (stainless steel)
1 x
Directions for use
20 x Seal-it lead bottle seals
1 x
Transport case
`
`
Check delivery for completeness and transport
damage.
`
`
Point out any damage in the packaging to the
freight forwarder/supplier immediately.
Assembly
1. Attach the adapter for sample bottles  onto the
sample bottle .
2. Place the free end of the suction hose together with
the hose weight in the liquid you are sampling.
Safe sampling
1. Activate the handle of the vacuum pump and pump
liquid into the sample bottle.
2. To complete sampling, press the valve lever  on
the vacuum pump.
3. Remove the adapter for sample bottles from the
sample bottle and seal it.
CAUTION!
After activating the handle, the pump will continue
to suck liquids. Liquid entering the instrument.
Bodily injury due to escaping liquid and damage to
the instrument.
`
`
Deaerate the pump with the valve lever in good
time.
CAUTION!
Liquid entering the instrument due to overfilling
or tipping. Bodily injury due to escaping liquid and
damage to the instrument.
`
`
Shut down and secure the instrument immedi-
ately.
`
`
Contact the dealer or manufacturer.
After taking the sample
Rinse the suction hose (together with the hose
weight), sample bottle and adapter for sample bottles
with a pH-neutral liquid.

Publicidad

loading

Este manual también es adecuado para:

5314-2000