� Left-side tubing
allowing sufficient length for connection. Then
bend the tubing using a tube bender to make the
attachment. (Fig. 38a)
(2) Switch the drain hose and drain cap.
Switching drain hose and drain cap
(Fig. 39a)
(b) Remove the screw fastening the drain hose
on the right side, and pull out the drain hose
to remove it. (Fig. 39a)
(c) Apply moderate force to pull off the drain cap
on the left side. (If you cannot pull it off by
hand, use a long-nose pliers.)
(d) Reattach the drain hose to the left side and
the drain cap to the right side. (Fig. 40a)
Drain hose
Slide the drain hose fully onto the drain pan outlet
until the drain hose edge is pushed into the insu-
lation. Check that the screw holes in the drain
bracket and the drain pan outlet are aligned and
securely in contact, then fasten them with the
screw. (After attaching the drain hose, check that
it is attached securely.) (Fig. 40c)
Drain cap
Use a Phillips screwdriver to push the drain cap in
firmly. (If it is difficult to push in, wet the cap with
water first.)
(3) Install the indoor unit on the rear panel.
(4) Connect the tubing and wiring led inside from out-
doors.
(5) After completing a leak test, bundle the tubing
together with armoring tape and store it inside the
tubing storage area at the back of the indoor unit
and hold it with clamps. (Figs. 40a and 41a)
All manuals and user guides at all-guides.com
Hole in wall
Insulation
Drain bracket
15
Wide tube
Bent part
Narrow tube
Fig. 38a
Drain hose
Fig. 39a
Drain cap
Fig. 40a
Screw hole
Drain bracket
Screw
Drain hose
Fig. 40c
Fig. 41a
Rear panel
Drain cap
Drain hose
Clamp
Drain pan outlet
Drain hose
Fig. 40b
Refrigerant tubing
Inter-unit wiring