Panasonic S-15MK2E5A Manual Del Usuario página 17

Ocultar thumbs Ver también para S-15MK2E5A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
7. APPENDIX
■ When Using Wireless Remote Controller Instead of Wired Remote Controller
When the wireless remote controller is to be used, slide the switch (S011) on the indoor unit control PCB to the ON position.
● If this setting is not made, an alarm will occur. (The operation lamp on the display blinks.)
Setting status
ON: Wireless: main, Wired: sub
OFF: Wired: main, Wireless: sub (at shipment)
■ Troubleshooting
If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly,
contact your dealer or a service center.
Indoor unit
Symptom
Sound like streaming water during
operation or after operation
Noise
Cracking noise during operation or
when operation stops.
Discharged air is smelled during
Odor
operation.
Dewdrop gets accumurated near air
Dewdrop
discharge during operation
Fog occurs during operation in cooling
mode.
Fog
(Places where large amounts of oil mist
exist at restaurants.)
Fan is rotating for a while even though operation stops.
Wind-direction changes while operating.
Wind-direction setting cannot be made.
Wind-direction cannot be changed.
When wind-direction is changed, flap operates several
times and stops at designated position.
Dust
Outdoor unit
Symptom
When power is turned ON instantly.
No operation
When operation is stopped and
resumed immediately.
Noise
Noise often occurs in heating mode.
Steam
Steam often occurs in heating mode.
When stopped by remote controller, outdoor unit fan is
sometimes operating for a while even though outdoor
compressor is stopped.
Slide
Sound of refrigerant liquid flowing inside unit
Sound of drainage water through drain pipe
Cracking sound due to temperature changes of parts
Indoor odor components, cigarette odor and cosmetic odor accumurated in
the air conditioner and its air is discharged.
Unit inside is dusty. Consult your dealer.
Indoor moisture is cooled by cool wind and accumulated by dewdrop.
Cleaning is necessary because unit inside (heat exchanger) is dirty.
Consult your dealer as technical engineering is required.
During defrost operation
Fan rotating makes operation smoothly.
Fan may sometimes rotates because of drying heat exchanger due to
settings.
When air discharge temperature is low or during defrost operation,
horizontal wind flow is made automatically.
Flap position is occasionally set up individually.
When long-hour operation is made with fixed wind-direction, wind-direction
is controlled automatically and flap position is occasionally changed.
When wind-direction is changed, flap operates after searching for standard
position.
Dust accumulation inside indoor unit is discharged.
Operation is not acticated for the first approx. 3 minutes because compressor
protection circuit is activated.
During defrost operation
Fan rotating makes operation smoothly.
17
Cause
Cause

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S-22mk2e5aS-28mk2e5aS-36mk2e5a

Tabla de contenido