Translation of the original instructions
15
Adaptor
16
Inductor
17
Pneumatic pedal connection
USB reprogramming socket
18
19
Outdoor temperature control connector (160LG)
20
Pneumatic pedal

FIRST USE

The POWERDUCTION 110LG is supplied with a 5 m power cable fitted with a 5 poles + 16 A 50/60 Hz plug.
The POWERDUCTION 160 LG is supplied with an 4 m power cable fitted with a 5 poles 32 A 50Hz/60Hz plug.
1. Once the product is assembled, place the torch on its support. Unscrew the inductor and the tank's cap.
2. Fill up the tank to the maximum using special welding liquid coolant (30 l / 7 l).
3. Take the lance and place it at the tank inlet or above the filling canister.
4. Connect the machine to the mains.
Switch on the machine (1).
5. The machine starts and will systematically display Error 6 or 7 («E-6» or «E-7»).
6. Press the accessory change button (10) twice. The purge cycle takes 5 seconds (a loading icon should be displayed
during it) and a double «beep» sound indicates completion.
7. As soon as the liquid is coming out of the torch, stop the torch by pressing the torch button, the accessory change
button or the heat authorisation button. Or wait for «E-6» to be displayed.
If Error 7 is displayed, start again from step 6 (five times max, see default E-7 explanation).
8. Screw the inductor by hand.
9. Press the accessory change button (10) twice. The purge cycle takes 5 seconds (a loading icon should be displayed
during it) and a double «beep» sound indicates completion.
10. The temperature of the cooling liquid and the power instruction are displayed.
11. Top up the tank with cooling liquid if required.
12. Replace the tank cap. The product is ready to operate.
Solving fault E-7
If the issue remains, check that the pump is working correctly or that the pipe is not blocked.
After five unsuccessful purge cycles, it is possible to:
- Stretch the torch above the machine to clear any pocket of water and for the pump to kick in.
- Put the machine at a 30° angle towards the torch.
- It is possible to blow the torch. Use an air blower and a cloth to keep it water proof and avoid projections.
- Re-attempt one or two cycles after each action.
If the issue remains, check that the pump is working correctly or that the pipe is not blocked.
INSTRUCTIONS
1. Set the main switch (1) to ON.
The machine initialises in 2 seconds.
2. Press the heat authorisation button (2) as described on page 7. The indicator on button (2) and the lance support LED
(12) both switch on, indicating that the machine is ready to operate.
3. Position the inductor (13) flat on the workpiece (place the open part of the ferrite towards the workpiece).
4. Press the button (11) on the lance or the pneumatic pedal to start the heating; if necessary move the inductor to
heat a larger area. Two indicators indicate that the heating is active:
- The brightness of the LED illuminating the inductor (12) decreases
- The minimum power indicator light on the heating power indicator (3) flashes quickly (in HI mode both min &
max lights flash).
Do not heat the same area for too long (a few seconds are sufficient depending on the thickness) to
prevent the metal piece from melting.
It is possible to change the rated power during the heating.
The heating set point can be set to Hi. The power is identical to the 100% mode but the Powerduction
behaves differently:
- At 100%: he wears the part red and maintains the right power for a few seconds before slowly rea-
ching its maximum power.
- In Hi mode: it rises to its maximum power regardless of the condition of the room to be heated.
Remain very vigilant, the heating is strong and fast and may damage the part without a control of
this mode.
* Valid only for Powerduction versions of V4 program versions. Previous versions are not equipped with this function.