Preventive Maintenance - GYS POWERDUCTION 110LG Manual Del Usuario

Ocultar thumbs Ver también para POWERDUCTION 110LG:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
Translation of the original instructions
Safety and fault setting of the device
- If the temperature input does not change after 5 s, the product goes into fault "E12".
-  If a thermocouple cuts out, then the regulation stops because the voltage U T° exceeds the maximum voltage of 4.9 V.
-  If the temperature drops significantly in a short period of time (when thermocouple probes are disconnected, for ex-
ample), the heating stops and the product goes into fault "E11".
-  To have the most accurate regulation possible, the measuring point(s) must be as close as possible to the inductor.
This is the reason for the 2 thermocouples on the external interface.
- The display shows the highest temperature measured by the sensors.
MAINTENANCE
General recommendations
• It is recommended to change the cooling liquid every two years, otherwise you may damage the Powerduction's lance.
Before adding the liquid, dust the product and check for leaks.
• Regularly check the tightening of the power screws and the appearance of the electrical power connections.
Recommended tightening torque for power screws
Dimensions screws
Material
Torque
• It is essential that the maintenance of the product is performed by qualified, authorised staff, that is fully aware of the
recommendations outlined in this manual.
• Never clean, lubricate or perform maintenance on the product when it's being used.
• Before any maintenance work, set the On / Off switch to « 0 » to switch off the machine, .then disconnect it it from
the mains power supply to prevent any electrical shock or other risks resulting from improper handling.
• Do not wear rings, watches, jewellery, hanging clothes (e.g. ties), torn clothes, scarves, unbuttoned or unzipped
jackets, or anyhting that could get caught during the operation of the machine
7 Nm

Preventive maintenance

Meticulous inspections should be carried out at regular intervals to quickly detect and eliminate faults, so they will not
cause damage to the device.
Prior to each use of the POWERDUCTION, check the unit's security systems and any anomalies that
may hinder the proper operation of the device. Perform daily checks to identify signs of wear.
The operational safety of the product can only be guaranteed if the repairs are carried out using ori-
ginal spare parts, and if the maintenance instructions are followed.
After each use and once the product is switched off, it should be cleaned immediately to remove any
dust or dirt that may impair cooling efficiency, affect the proper functioning of the product and reduce
its lifespan.
Before each use, check the good operation of the main systems, security systems, and all the electrical
cables connection.
Perform periodic visual inspections to verify that there are no cooling liquid leaks, and check that the
vents are not obstructed.
34
POWERDUCTION 110LG / 160LG
M5
M6
M8
steel
steel
brass
4 Nm
6 Nm
7 Nm
• Rather wear clothing specifically designed for the prevention of accidents, such as:
non-slip shoes, anti-noise helmets, protective goggles, safety shoes, etc ...
• Never use petrol or flammable solvents to clean the product. Prefer the use of wa-
ter and, if necessary, non toxic commercial solvents.
• After maintenance, always put and secure the metal covers back on, before swit-
ching the machine on.
• The ferrite on inducer can be replaced if damaged.
Gas
1/4
M10
clamp
Gas
3/8
brass
7 Nm
2,5 Nm
4 Nm
Inductor
M28
M32
16/22
copper
copper
copper
by hand,
7 Nm max
7 Nm max
4 Nm max
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Powerduction 160lg

Tabla de contenido