Technical data
No-load speed
On-load speed
Max. Ø paddle
Max. rec. mixing quantity
Weight incl. battery
recomm. Metabo-Li-Ion
battery

Machine components

1 Unlocking mechanism for ON / OFF switch
2 ON / OFF switch
3 Unlocking mechanism for battery
4 Metal frame
5 Handles
6 Battery pack
7 Drive shaft
8 HEXAFIX coupling (Paddle connexion)
9 Paddle
10 Capacity indicator button
Read and observe the operating
instructions for the machine before
you start it up!
Always wear protective goggles
and ear protection while working.
It is advisable to wear a dust mask
whenever working with materials
which generate large amounts of
dust.
Always wear protective gloves
while working.
Xo 10
NC
- 760 min
-1
- 640 min
-1
4.7" / 120 mm
-10 gal. / -40 Ltr.
9.3 lbs / 4,2 kg
18 V, 5,2 Ah
CE Declaration of Conformity
We declare, with sole responsibility, that
this product complies with the following
standards or normative products: EN ISO
12100:2010;
EN
55014-1:2006+A1:2009; EN
55014-2:1997+A1:2001+A2:2008; 60745-1:2009
+A11:2010 in accordance with the provisions of
directives 2014/30/EU, 2006/42 EC, 2011/65/EU.
Gaimersheim, 2017-05-03
Alexander Essing
Managing Director
Technical documentation can be requested from:
Collomix GmbH
Abt. Technische Entwicklung
Daimlerstr. 9, 85080 Gaimersheim, Germany
Noise/vibration levels
Measured values determined in accordance with EN
62841-2-10:2016. The A-weighted noise level of the
machine is typically:
Sound pressure level
L
[dB(A)]
pA
Xo 10 NC
76 dB(a)
Uncertainty K = 3 dB
Overall vibration level (for mixing of mineral
materials)
Emission level a
Xo 10 NC
Uncertainty K = 1,5 m/s
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
 Emissions values
These values make it possible to assess the emis-
sions from the power tool and to compare differ-
ent power tools. the actual loaad may be higher or
lower depending on the operating caonditions, the
condition of the power tool or the accessories.
Please allow for breaks and perionds when the
load is lower for assessment purposes. Arrange
protiective measures for the user e.g. organisation-
al measures based on the adjusted estimates.
Sound power level
L
[dB(A)]
WA
87 dB(A)
[m/s
2
]
n
0,6 m/s
2