9. Specifications
Output signal 4 ... 20 mA, HART
PROFIBUS
PA
®
7)
Transmitter model (selectable versions)
Data sheet
Output
4 ... 20 mA
HART
protocol
®
FOUNDATION™ Fieldbus and
PROFIBUS
PA
®
Connection method
1 x 2-wire, 3-wire or 4-wire
Measuring current
Measuring insert (replaceable)
Material
Diameter
Spring travel
Response time (in
water, per EN 60751)
Neck tube
Material
Connection thread to
the thermowell
Connection thread to
the head
Neck length
7) Protect the temperature transmitter from temperatures > 85 °C.
8) Not for 2 x 4-wire connection method
WIKA operating instructions models TR12, TC12
protocol, FOUNDATION™ Fieldbus and
®
T15
TE 15.01
x
x
< 0.2 mA
Stainless steel 1.4571, 316/316L
Standard: 3 mm
, 6 mm, 8 mm (with sleeve)
8)
Option (on request): 1/8"
approx. 20 mm
t
< 10 s
t
< 20 s (measuring insert diameter 6 mm: The thermowell
50
90
required for operation increases the response time dependent upon the
actual parameters for the thermowell and the process.)
Stainless steel 1.4571, 316/316L
G 1/2 B, G 3/4 B, 1/2 NPT, 3/4 NPT, M14 x 1.5, M18 x 1.5, M20 x 1.5,
M27 x 2
M20 x 1.5 with counter nut
M24 x 1.5 with counter nut
min. 150 mm, standard neck length
200 mm
250 mm
other neck lengths on request
T32
T53
TE 32.04
TE 53.01
x
x
x
x
x
< 0.3 mA
< 0.2 mA
(3.17 mm), 1/4" (6.35 mm), 3/8" (9.53 mm)
8)
1/2 NPT
3/4 NPT
TIF50, TIF52
EN
TE 62.01
x
x
x
< 0.3 mA
23