SPECIFICATIONS
Maximum SurgeWatts ..................
8,500 watts
Continuous Wattage Capacity ............
5,500 watts
Power Factor ................................
1.0
Rated Maximum Continuous AC Load Current:
At 120Volts .........................
45.8 Amps
At 240 Volts .........................
22.9 Amps
Phase ..................................
I-phase
Rated Frequency .........................
60 Hertz
FuelTank Capacity ....................
7 U.S.gallons
ShippingWeight ..........................
152 lbs.
GENERAL
MAINTENANCE
RECOMMENDATIONS
The Owner/Operator
is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis;that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate
a
damaged or defective generator.
Engine
Maintenance
See
engine
owner's
manual for
instructions.
_k
AUTION!
Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES.RETURN
USED OIL TO COLLECTION CENTERS.
Generator
Maintenance
Generator
maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment
where it will not be exposed to excessive
dust, dirt, moisture or any corrosive
vapors. Cooling air
slots in the generator
must not become clogged with snow,
leaves or any other foreign material.
NOTE:
DO NOT use a garden hose to clean generator.
Water
can enter engine fuel system and cause problems. In
addition, if water enters generator
through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator
internal windings will eventually
decrease the insulation resistance of these windings.
Generator
Cleaning
_k
AUTION!
NEVER insert any object or tool
through the air cooling slots, even if the engine is
not running.
• Use a damp cloth to wipe exterior surfaces clean.
• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Use low pressure air (not to exceed 25 psi) to blow
away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
STO RAG E
The generator
should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than 30 days,
use the following guidelines to prepare it for storage.
Generator
Storage
• Clean the generator as outlined in "Generator Cleaning".
• Check that cooling air slots and openings on generator
are open and unobstructed.
_k
AUTION!
Storage covers can be flammable.
DO NOT place a storage cover over a hot
generator. Let the unit coot for a sufficient time
before placing the cover on the unit.
Engine Storage
See
engine
owner's
manual for
instructions.
Other
Storage
Tips
• To prevent gum from forming in fuel system or on
essential carburetor parts, add fuel stabilizer into fuel
tank and fill with fresh fuel. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
• DO NOT store fuel from one season to another unless
it has been treated as described above.
• Replace fuel container
if it starts to rust. Rust and/or dirt
in fuel can cause problems if it's used with this unit.
• Store in clean and dry area.