The cooling and lubrication of the drilling process must be metered to the tool used. Ensure that no more
than the required coolant / lubricant quantity is used and that it does not get into the magnetic drilling
unit. Magnetic drilling units must be stored in a horizontal position after completion of work so that the
gear grease is distributed evenly again.
Switching the drilling machine on and off
The control panel of your magnetic drilling machine is designed
for optimum operation and safety.
1 – The ON switch (GREEN):
This (right) switch is used to switch the motor unit ON ("l").
2 – The OFF switch (RED):
This (left) switch is used to switch the motor unit OFF ("O").
3 – The magnetic switch (RED):
This switch is used to control the main current
supply and to switch the magnet ON and OFF.
Activate magnet
Place the drilling machine on the base.
Press the RED switch ("-") to activate the magnet.
Switching the motor on and off
The motor unit can only be switched on when the magnet is activated. To switch the motor ON press the
GREEN button ("l"). To switch the motor OFF press the RED button ("O").
Maintenance and care
Caution! First remove the mains plug from the socket. The magnetic drill stand must be kept clean and
should be cleaned regularly. To avoid accidents, the drill stand, connection cables, protective conductor
connections, plugs and sockets, switches and automatic start lock must be checked regularly for dam-
age. Note: Also observe the maintenance and care instructions for the attached electric tools. Damaged
machine parts are only to be replaced by original spare parts. All sliding surfaces of the guide must be
oiled quarterly, after cleaning. Should side play occur, this can be compensated by adjusting the grub
screws. For optimum cooling, the ventilation slots of the drill drive must be kept free of dirt and dust.
Please note that electrical equipment may only be repaired, maintained and checked by qualified electri-
cians (in accordance with VBG4), as improper repairs can cause serious danger to the user!
1. On
2. Off
3. Magnetic