Toshiba RAV-GP801AT-E Manual De Instalación página 10

Ocultar thumbs Ver también para RAV-GP801AT-E:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
CAUTION
This air conditioner adopts the HFC refrigerant (R32) which does not
destroy the ozone layer.
• R32 refrigerant has a high working pressure and is apt to be affected
by impurities such as water, oxidizing membrane, and oils. Therefore,
during installation work, be careful that water, dust, previous
refrigerant, refrigerating machine oil, or other substances do not enter
the R32 refrigeration cycle.
• Special tools for R32 or R410A refrigerant are required for installation.
• For connecting pipes, use new and clean piping materials, and make
sure that water and/or dust does not enter.
Cautions for outdoor unit installation space
• In the event that the outdoor unit is installed in a small space and
refrigerant leaks, accumulation of highly concentrated refrigerant may
cause a fire hazard. Therefore, be sure to follow the installation space
instructions in the Installation Manual, and provide open space on at
least one of the four outdoor unit sides.
• In particular, when both the discharge and intake sides face walls and
obstacles are also placed on both sides of the outdoor unit, take steps
to provide space wide enough for a person to pass (600 mm or more)
on one side to prevent leaked refrigerant from accumulating.
Obstacle
600 mm or more
EN-17
Building or wall
Outdoor unit
Obstacle
Building or wall
To disconnect the appliance from main power supply
• This appliance must be connected to the main power supply by means
of a switch with a contact separation of at least 3 mm.
Do not wash air conditioners with pressure washers.
• Electric leaks may cause electric shocks or fires.
(*1) Refer to the "Definition of Qualified Installer or Qualified Service Person."
- 9 -
EN-18

Publicidad

Tabla de contenido
loading

Tabla de contenido