Problem
A previously suc
cessfully con
nected battery
pack is no longer
able to control
the mobile dust
extractor.
40
Possible causes
The mobile dust extractor
was switched on using the
battery pack and switched
off using the remote con
trol. The switch-off signal
from the remote control
takes priority over the pre
viously connected battery
pack, so the connection to
the battery pack is lost.
Remedy
control can be connected to
the mobile dust extractor
again (see chapter 6.2Re
mote control)
Connecting the battery
pack to the mobile dust ex
tractor
See chapter
6.3