Optional Accessories - Telstar Bio II Advance Serie Manual Del Usuario

Cabinas de seguridada microbiológica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.8.

OPTIONAL ACCESSORIES

Active Carbon Filter (Annex A4.2) (Additional fan installation required)
Canopy (Annex A4.4)
Support table (both models for 770 mm and 900 mm height working area).
UV kit
Easy-to-work microprocessor-controlled UV germicidal lamp with a timer function. It can only
be enabled in the Disinfection screen (Chapter 4.5 point 3.1) or by means of the UV light
Auto Power on screen (Chapter 4.5 point 4.4).
Average disinfection intensity over the work zone of 200 µW/cm2 with 20% depreciation
after a working life of 8000 hours.
GS has not been tested for Active Carbon Filter, Canopy neither UV kit.
WARNING
In the event of using this accessory, you should consider the normal precautions in the use
of these types of lamps. Their use is only suitably for previous external sterilisation of
materials introduced in the cabinet. That is why the lamp is a previous accessory to working
in the cabinet and it is essential to keep it turned off when the operator is in front of the
working area or working on it. The SECURIT glasses provide protection from direct radiation
but UV rays are reflected on polished metal parts and can seriously damage an operator's
eyes. That is why the glass front must be into the closed position to be able to switch on the
U.V light, then automatically the fans will disconnect.
Vacuum tap kit.
Gas tap kit.
GS has not been tested for Vacuum tap neither Gas tap kit.
WARNING
Gas is a toxic and inflammable substance which in the event of an accident can cause serious
damage to the user and the cabinet.
The presence of a flame within the cabinet creates turbulence which affects its control and
proper functioning, therefore we recommend you do NOT use burners unless strictly
essential and if the user is prepared to assume this responsibility.
Gas connection should be done in line with the safety standards of each country, region and
company.
For these reasons, the electrically controlled valve that enables gas entry can only be
activated when the fans are working and it is automatically disconnected when the alarm
indicating a lack of impulsion flow is activated.
UM-BIOIIADVANCE-EN-1302
All manuals and user guides at all-guides.com
26

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bio ii advance 3Bio ii advance 4Bio ii advance 6

Tabla de contenido