GB
TECHNICAL DATA
- Minimum dynamic pressure . . . . . . . . . . . . . . . 0.5 bar
- Recommended working pressure (static) . . . . . . 1-5 bar
(P.S.: for pressures higher than 5 bar we recommend
to install a pressure reducer)
- Feeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Volt
- Rinsing time (adjustable with remote control) . . . 6 sec.
- Activation distance from the pre-set sensor . . . . 550 mm
(adjustable)
- Automatic activation every 24 hours
INSTALLATION (Fig.A➝F)
- Don't install the tap in front of a mirror or at an infrared
electronic system.
- Keep a minimum distance of 1.5 meters between the tap
and other objects.
- Prepare a suitable hole in the wall in order to contain the
built-in box. The installation quotes are noted in fig. A (the
admissible built-in depth regards the finished wall including
the covering)
- Connect the piping, open the closing valve inside the box
and check the tightness of the connections.
- For the transformer model, provide the possibility o fan
electric connection between de built-in box and the current
socket (maximum distance 5 meters) (see fig. F)
- Finish the plaster again and apply the covering taking care
to safeguard the box area.
- Close the closing valve, disassemble the brass joint inside
de box and assemble in its place the plastic joint provided
with a solenoid valve (take care of the assembling
directions identified by an arrow)
- Remove the lid from the box and assemble the outer plastic
frame fixing it with the equipped screws and dowels.
- Connect the solenoid valve to the electronic part and
connect the feeding (introduce the 9 Volt battery or
introduce the transformer in the 220 Volt electric socket)
- Open again the closing valve
- Assemble the outer plate and fix it with the lower dowel
(2.5 mm Allen key)
- Remove the adhesive placed on the sensor and check the
functioning of the tap.
ACTION RANGE ADJUSTMENT OF THE SENSOR
(Fig.G)
- Disassemble the outer plate and disconnect the feeding.
- Pass four times the hand in front of the sensor
- Connect again the feeding
- Place the hand in front of the sensor at a distance of about 5-
10 centimeters (the red light of the sensor will start flashing
slowly) within 5 seconds after the reconnection of the feeding.
- Wait till the red light of the sensor flashes quickly; now
move the hand at the desired action distance and wait for
the light to stop flashing.
- Check the correct result of the adjustment; repeat the
operations if it is not correct.
REPLACEMENT OF THE SOLENOID VALVE (Fig.H)
- Disassemble the outer plate and disconnect the solenoid
valve from the electronic part.
- Close the closing valve
- Unscrew the solenoid valve with a 25 mm wrench and
replace it with the new one taking care that there doesn't
remain dirt among the tightness and the seal surfaces.
- Assemble everything again on the contrary.
REPLACEMENT OF THE ELECTRONIC PART
(Fig.I)
- Disassemble the outer plate and close the closing valve
- Disconnect the solenoid valve from the electronic part
- Unscrew the nuts with a 7mm wrench and disassemble the
electronic part.
- Replace the electronic part and assemble everything again
on the contrary.
REPLACEMENT OF THE BATTERY (Fig.L)
- When the battery runs out, the red light of the sensor starts
flashing constantly; the battery has to be replaced within
two weeks.
- Disassemble the outer plate, disassemble the lid and
replace the battery (alkaline or lithium)
- Proceed on the contrary and check the functioning of the
tap.
REMOTE CONTROL (option)
Different operations can be carried out through the remote
control, positioning it in front of the sensor at a distance of
about 5cm
RANGE:
press + o – to increase or decrease the action
range of the sensor
FLOW TIME: press + o – to increase or decrease the supply
time.
DELAY IN:
press + o – to increase or decrease the
recognition time for the presence of an user.
DELAY OUT: press + o – to increase or decrease the time
difference when you leave the action range of
the sensor and the supply start.
ON/OFF:
press to block the tap for 1 minute in closing
position.
RESET:
press the key together with key + to reset all the
adjustments to the parameters of the factory.