Laying The Connecting Cables - Dometic B 16000PLUS Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
B1600PLUS, B2200, B2600
8.3
Installing in a roof hatch opening already provided
I
NOTE
 Existing roof hatch openings in accordance with fig. 3 are
suitable for installing the roof air conditioner.
 Dispose of all waste material, glue, silicone and seals sepa-
rately. Observe the disposal guidelines.
 The manufacturer only assumes liability for parts included in
the scope of delivery. The validity of the warranty expires if the
device is installed together with third-party parts.
See fig. 6
➤ Remove all screws and fixtures of the existing roof hatch.
➤ Take out the roof hatch.
See fig. 7
➤ Remove the sealant around the opening using a scraper or similar tool.
See fig. 8
A
NOTICE!
Observe the sealant manufacturer's instructions.
➤ Seal the screw holes and recesses with a flexible non-hardening butyl
sealing compound (e.g. Sika-Lastomer-710).
8.4

Laying the connecting cables

D
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
The roof air conditioner must be connected to an electric circuit which is able
to supply the required current (see chapter "Technical data" on page 38).
➤ Select the cross-section of the cable corresponding to the length:
– Length < 7.5 m: 1.5 mm²
– Length > 7.5 m: 2.5 mm²
EN
All manuals and user guides at all-guides.com
Installation
31

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

B 2200B 2600

Tabla de contenido