Checking The Interior Parts Of The Device; Cleaning The Interior Parts Of The Device; Assembling The Nail Setting Tool - DeWalt DDF2130000 Traducido De Las Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
English
Push the piston guide into the receptacle on
the device (1) and unscrew it (2).
5.2 Checking the interior Parts of
the Device
Check the interior parts of the device in
accordance with the following table. Replace
worn parts.
Wearing part
Piston return spring
Sealing ring
Piston
5.3 Cleaning the interior Parts of
the Device
Clean the piston guide from the outside
using a hand-held wire brush (1).
Clean the piston guide and the receptacle on
the device from the inside using a round wire
brush (2).
Clean the piston from the outside using
a hand-held wire brush (3).
40
All manuals and user guides at all-guides.com
1
2
Inspection
Length (at least
161 mm)
Condition (cuts, general
wear)
Thickness (at least
4 mm)
Condition (cuts, general
wear)
Splinters and damage
2
5.4 Assembling the Nail Setting
Tool
Mind the position of the groove when inserting
the piston guide.
Press the piston guide into the receptacle (1)
and screw it tight (2).
Insert the piston with sealing ring and the
piston return spring into the piston guide.
Screw the magazine or the single-shot
attachment onto the piston guide until you
hear the fi rst „click" - then turn one more
time. (By using single shot attachment,
tighten till it stops.)
1
3
1
2

Publicidad

Tabla de contenido
loading