⑩ MAIN SWITCH: It is a 2-position selector that
energises the machine if to (I)ON.
the machine is de-energised if to (0) OFF.
12 V battery model:
⑩ - MAIN SWITCH:
(I) ON: machine works on mains power
(0) OFF: the machine is unpowered
(II) ON: machine works on battery power
⑪ BOILER ON button: press to turn the boiler
on.
⑫⑬ THERMO REGULATOR: refer to paragraph
OPERATION
1 Boiler cleaning
2 Visual checks
3 Cleaning the
burner
4 General clea-
ning
personnel
at
dry steam ;
MACHINE PART
1 Remove limestone from the boiler
1 Clean the water level sensors
2 Machinery + gun
2 Electrical parts
2 Integrity of the water and steam
hoses and gun
3 Ignition electrodes, Diesel nozzle
4 External cleaning
the
"Temperature adjustment".
⑭ Display:
- Temperature indicator
- Indicates "H2O" when water is missing from
the tank.
- Indicates "GAS" when diesel is missing from
the tank.
>
Steam gun
Use of the steam gun
- Plug the lance jack into the appropriate so-
cket and lock it with the two levers;
- To obtain a spray of steam, press the trigger
on the pistol grip;
• WARNING:
- For any subsequent adjustment, setting or
replacement of parts not foreseen in this
manual, please contact qualified personnel
at the manufacturer or resale outlet.
- Before carrying out any replacement, ensure
that the main switch is in the (0) OFF position.
> START-UP
Description of the start sequence
After carrying out all the connections and pre-
ventative inspections described in the pre-
vious chapters, start the machine according
to the following instructions:
1) Before starting the generator, fill the tanks
with water and DIESEL up to the set level.
PERIODICITY
1 Every year
1 Every three
months
2 Every week
2 Every mont
3 Every year
4 Every week
22
Authorized After Sales
Service
The user
The user
Authorized After Sales
Service
The user