Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home
structure and must not terminate beneath the mobile home. Terminate the exhaust vent
outside.
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best drying performance
Use the following Vent system chart to determine type of vent material and hood
combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust
systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and increased energy usage.
The Vent system chart provides venting requirements that will help to achieve the best drying
performance.
All manuals and user guides at all-guides.com
Vent system chart
NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine
maximum exhaust length, add one 90º turn to the chart.
1. Install exhaust hood. Use caulking compound to seal exterior wall opening around
2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust
3. Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in
1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place
Number of 90º
Type of vent
turns or elbows
0
Rigid metal
Flexible metal
1
Rigid metal
Flexible metal
2
Rigid metal
Flexible metal
3
Rigid metal
Flexible metal
4
Rigid metal
Flexible metal

Install Vent System

exhaust hood.
hood with 4" (10.2 cm) clamp.
"Plan Vent System." Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior of the vent to secure vent.

Install Leveling Legs

WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
cardboard under the entire back edge of the dryer.
Box or louvered
Angled hoods
hoods
64 ft (20 m)
58 ft (17.7 m)
36 ft (11 m)
28 ft (8.5 m)
54 ft (16.5 m)
48 ft (14.6 m)
31 ft (9.4 m)
23 ft (7 m)
44 ft (13.4 m)
38 ft (11.6 m)
27 ft (8.2 m)
19 ft (5.8 m)
35 ft (10.7 m)
29 ft (8.8 m)
25 ft (7.6 m)
17 ft (5.2 m)
27 ft (8.2 m)
21 ft (6.4 m)
23 ft (7 m)
15 ft (4.6 m)