2.2 START-UP
2.2.1 CONNECTION OF THE REMOTE CONTROL AND SELF-CALIBRATION
The In-Wash remote and the In-Tank remote are linked at the factory. It is only necessary to follow the following steps:
CR 2032 (x2)
1.
Place the batteries inside the remote control.
2.
Open water supply valve
Activate the power to supply the In-Wash + In-Tank.
3.
In case it is necessary to link the remote controls again (due to the proximity to another device in a nearby room, by replacing the remote control, etc.):
1
ON
1.
Disconnect the appliance from the power. Reconnect the appliance to the power.
2.
Once the power supply is connected, you have 60 seconds to link the remote control by pressing the Stop / Stop button on the In-Wash remote
control for 5 seconds. To link the In-Tank, press the full download button for 10 seconds.
3.
A "beep" is heard and all the LEDs on the remote light up, indicating that it has been linked to the e-bidet. From this moment on, the device ca-
rries out a self-calibration process that lasts 120 seconds and during which water comes out of the cannula area. The In-Tank will perform a small
download indicating its correct pairing.
Do not disconnect the appliance during this process.
2.2.2 USE OF THE PRODUCT
When the product is first connected to the mains, it is necessary to wait at least 4 minutes to be able to perform the first discharge of the toilet.
The In-Wash has a small internal water tank that is cold in stand-by conditions.
When the user detector detects a seated user, the preheating process is activated.
The preheating takes place at 36º. The functions may be activated at any time, but if they are activated too soon, the water will not have time to reach
the established temperature; therefore it is recommended a minimum preheating period of 30 seconds from the moment the In-Wash detects the user
until any water function is activated.
When a function is activated, the In-Wash carries out a cleaning of the nozzle before its use.
When the function is finished, a subsequent cleaning process of the nozzle takes place for 10 seconds.
The functions may only be activated when the cover is open and the device detects a user.
See Fig. 2
It is possible to modify the pre-set standard values, customising them to suit the customer´s needs. See section 3.4.1
When pressing any button of the remote control, the leds are activated, informing us of the active function and the settings that have been selected.
The leds switch off 5 seconds after showing that information.
1
CR 2032 (x1)
2
Max. 60 s.
5 s.
10 s.
2
3
ON
3
SELF-CALIBRATION
120 s.
19