TROUBLESHOOTING

Save t ime and money! Review t he chart s on t he following pages first and you may not need t o call for service.
Problem
Dehumidifier does not st art
Dehumidifier does not dry
t he air as it should
Dehumidifier runs t oo much
Frost appears on t he coils
Fan noise
Wat er on floor
Bucket Full LED light
flashing and alarm sounds
while drain hose is
connect ed.
10
Possible Cause
The dehumidifier is unplugged.
The fuse is blown/ circuit breaker is
t ripped.
Dehumidifier has reached it s set
humidit y level or bucket is full.
Bucket is not in t he proper posit ion.
Power Failure.
Did not allow enough t ime t o remove
t he moist ure.
Airflow is rest rict ed.
Dirt y Filt er
The Humidit y Cont rol may not be set
low enough.
Doors and windows may not be
closed tightly.
Clothes dryer may be blowing
moisure- laden air into the room.
Room t emperat ure is t oo low.
Area t o be dehumidified is t oo large.
Doors and windows are open.
Room t emperat ure is below 41 ° F
(5 ° C)
Air is moving t hrough t he
dehumidifier.
Hose connect ion may be loose.
Int ended t o use t he bucket t o collect
wat er, but a hose was at t ached.
Drain hose not t ight on fit t ing.
Drain hose is kinked.
What To Do
Makes sure t he dehumidifier's plug is pushed complet ely int o
t he out let .
Check t he house fuse/ circuit breaker box and replace t he fuse
or reset t he breaker.
The dehumidifier aut omat ically t urns off when eit her
condit ion occurs. Change t o a lower set t ing or empt y t he
bucket and replace properly.
The bucket must be in place and securely seat ed for t he
dehumidifier t o operat e.
There is a prot ect ive t ime delay (up t o 3 minut es) t o prevent
t ripping of t he compressor overload. For t his reason, t he unit
may not st art normal dehumidificat ion for 3 minut es aft er it
t urned back on.
When first inst alled, allow at least 24 hours t o maint ain t he
desired dryness.
Make sure t here are no curt ains, blinds or furnit ure blocking
t he t op or back of t he dehumidifier. See t he Choosing a
Locat ion sect ion.
See t he Care and Cleaning sect ion.
For drier air, press t he
pad and set t o a lower percent value
(%) or at t he Nonst op set t ing for maximum dehumidificat ion.
Check t hat all doors, windows and ot her openings are
securely closed.
Inst all t he dehumidifier away from t he dyer. The dryer should
be vent ed t o t he out side.
Moist ure removal is best at higher room t emperat ures.
Lower room t emperat ures will reduce t he moist ure removal
rat e. Models are designed t o be operat ed at t emperat ures
above 41°F (5°C).
The capacit y of your dehumidifier may not be adequat e.
Close all doors and windows t o t he out side.
Please operat e unit at t emperat ures above 41 F (5 C). Frost
will usually disappear wit hin 60 minut es. Under cert ain
condit ions, frost may appear on t he coils of your dehumidifier
at t emperat ures above 41°F (5°C). This is normal and frost
will usually disappear wit hin 60 minut es. See t he Aut omat ic
Defrost sect ion.
This is normal.
Check t he hose connect ion. See t he Removing Collect ed
Wat er sect ion.
Disconnect t he hose if using a bucket t o collect wat er. See
t he Removing Collect ed Wat er sect ion.
Check drain hose connect ion.
Ensure t he drain hose is point ed st raight down t o t he floor
and is not kinked in anyway.