Specifications

Installation Requirements

The E series oven can be installed in a standard or flush
inset application. If a cooktop is installed above an oven,
a minimum of 6 mm is required between the units. The
location of the electrical supply within the oven opening
may require additional cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
Min Base Support
TRIM OVERLAP
Top
Bottom
Sides

Electrical Requirements

Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the oven can be placed in an adjacent cabinet
within reach of the conduit.
Performance may be compromised if the electrical supply
is less than 240 volts.
The oven is supplied with a single phase and 3-phase con-
vertible power inlet box. The wiring diagram covering the
control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS
115 kg
REQUIRED POWER SUPPLY
Single phase
220–240 V AC, 50/60 Hz
3-phase
25 mm
Maximum Connected Load
0 mm
18 mm
Total Amps
Maximum Amps per Line
RATING
PLATE
Rating plate location
IMPORTANT NOTE: Connection of this appliance should
be through a fused connection unit or a suitable isolator,
which complies with national and local safety regulations.
The on/off switch should be easily accessible after the
appliance has been installed. If the switch is not accessible
after installation (depending on country) an additional
means of disconnection must be provided for all poles of
the power supply. When switched off there must be an all
pole contact gap of 3 mm in the isolator switch. This 3 mm
contact disconnect gap must apply to any isolator switch,
fuses and/or relays according to EN60335.
CAUTION
The supply wiring must be protected to withstand
temperatures up to 100°C.
380–415 V AC, 50 Hz
4.8 kW
20
15
wolfappliance.com | 3