KRAFTWERK 505.003.170 Manual De Uso Y Mantenimiento página 27

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
8.1.2 high beam pattern
"E": zero point of beam setter (centre of
headlamp). This
point is the basis for the measured values.
Deviations are
measured from this point.
"F": tolerance range. The high beam hot spot
should be
within this range.
"G": hot-spot.
"H": horizontal distance of hot spot from
centre point.
Possible units:
%, cm / 10 m, degrees
"I": vertical distance of hot spot from center
point. Possible units:
%, cm / 10 m, degrees
8.1.3 Fog beam pattern
The fog lamp is measured in a similar manner to
the low beam, the difference being that the bright-
dim does not have a break point but takes the
form of a continuous horizontal line.
8.1.4 Intelligent beam
the introduction of intelligent headlamp systems,
the accuracy of the headlamp configuration plays
an increasingly important role. To be able to
accurately set these headlamps, the vehicle
manufacturers have provided a special
configuration screen for these headlamps. This
must be selected with a diagnostics device
8.1.4.1 Headlamps with Dynamic light Assistance
Left DLA headlamp
projection
"A": deviation of the bright-dim border in
horizontal direction from the median. The
value is always
shown as an absolute value. Possible units:
%, cm / 10 m, degrees
"B": deviation of the bright-dim border in
vertical direction from the median. The value is
always shown as an absolute value.
Possible units:
%, cm / 10 m, degrees
8.1.4.2 Matrix function headlamp
Left Matrix headlamp
projection
"C": deviation of the bright-dim border in
horizontal direction from the median. The value
is always shown as an absolute value in angle
minutes
27
Right DLA headlamp
projection
Right Matrix
headlamp projection

Publicidad

Tabla de contenido
loading

Productos relacionados para KRAFTWERK 505.003.170

Tabla de contenido