GB
8.4
Operating KPZ 51E-7
Setting zero
If there is no load on the scale the display shows 0,0, then press 0. It is possible up to
2% maximum capacity.
Tare
If only required weight should appear eg. Container content, then empty container should
be placed on the scale and pressed
. The scale shows 0,0. On the display will appear
symbol NET. After filling up only contens will be show.
Available mulible tare function.
Available part tare function.
Deleting tare: remove the whole Weight from the scale and press
. On the display will
▼
appear symbol
GROSS.
Changing gross/ nett
▼
To show total container Weight and contents press button
.
GROSS sign will appear
and total weight will be shown. Next it should be pressed button
, PN the display will
appear the Weight of the contents and symbol NET.
Printing/ data entering
Pressing the button any data will be send to interfejs (option) or printing (option).
▼
Load weight is entered print memory. On the display will appear symbol
M+.
Completed print: Scale must be loaded and on the display will appear symbol 0. Next
within 1 second twice press button .