Name
Description
Average external temperature [°C] when switching
AP073
from summer/winter mode (with outside sensor)
Force summer mode (with outdoor sensor). Sanitary
(DHW) enabled and heating disabled.
AP074
0: Auto according to AP073
1: Summer
Building insulation level (with outside sensor)
AP079
0: Poorly insulated building
15: Well insulated building
External temperature [°C] below that at which anti-
AP080
frost protection is activated
AP082
Not used
Type of outdoor sensor used:
0: Auto
1: Wired sensor
AP091
2: Wireless sensor
3: Internet measured
4: None
Configuration of boiler blocking input contact X15 (al­
so see setting AP001)
AP098
0: Normally open
1: Normally closed
CP000
Max. settable heating setpoint temperature [°C]
Zone function
CP020
0: Disabled
1: Enabled
Comfort mode heating curve offset (with outside sen­
CP210
sor)
CP230
Heating curve slope (with outside sensor)
Number of days required for the screed drying pro­
CP470
gram
CP480
Screed drying starting temperature [°C]
CP490
Screed drying stop temperature [°C]
Zone control strategy selection
0: Automatic
CP780
1: Room Temp. based
2: Outdoor Temp. based
3: Outdoor & room based
Maximum fan speed in domestic hot water mode
DP003
[rpm]
Anti-legionella function
0: Disabled
DP004
1: Weekly
2: Daily (only available with Room Unit)
Difference between the flow temperature and the
DP005
temperature requested by the calorifier tank [°C]
Difference between the temperature detected by the
DP006
calorifier tank sensor and the desired DHW tempera­
ture that enables a heat request [°C]
Position of three-way valve in standby
DP007
0: CH operation
1: DHW (Domestic Hot Water)
Corrects in a negative sense the value measured by
DP034
the calorifier tank sensor [°C]
7804841 - 02 - 20012022
Factory
Minimum
value
22
10
0
3
0
-10
-30
0
0
1
0
80
25
1
15
15
1.5
0
0
0
20
20
20
20
0
See chapter
"Service Set­
tings"
0
15
0
4
2
1
0
0
en
9 Settings
Maximum Level
30
User
User
15
Installer
+25
Installer
Installer
Installer
1
Installer
80
Installer
Installer
90
Installer
4
Installer
30
Installer
50
Installer
50
Installer
Installer
Installer
User
25
Installer
15
Installer
Installer
10
Installer
INIDENS
189